Patient-Specific Instrumentation Does Not Improve Alignment Compared to the Extramedullary Foot Holder for the INBONE II Total Ankle Arthroplasty

In this study of stemmed TAA implants, surgeons achieved alignment generally consistent with PSI predictions. PSI adequately predicted implant size. For most cases, PSI achieved similar alignment and correction of deformity compared with standard instrumentation. PSI did not improve radiographic alignment compared with traditional instrumentation and was associated with longer operative times, possibly reflecting the primary surgeon's early experience with the technique. Each surgeon should select PSI or the standard jig based on their experience and preference.

Authors

Institutions

Publication Details

Journal
Foot & Ankle International
Published
2025-07-24
DOI
https://doi.org/10.1177/10711007251353787
Citations
1
Primary Topic
Foot and Ankle Surgery
Type
article
Field-Weighted Citation Impact
1.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Patient-Specific Instrumentation Does Not Improve Alignment Compared to the Extramedullary Foot Holder for the INBONE II Total Ankle Arthroplasty

Charlotte H. Jones, Allison L. Boden, Suzy Wang, Matthew S. Conti et al.
1 citations
Foot & Ankle International
Foot and Ankle Surgery
1.72
article

Patient-Specific Instrumentation Does Not Improve Alignment Compared to the Extramedullary Foot Holder for the INBONE II Total Ankle Arthroplasty

Charlotte H. Jones, Allison L. Boden, Suzy Wang, Matthew S. Conti, Scott J. Ellis, Constantine A. Demetracopoulos, Patricia Friedmann, Jensen K. Henry, Jonathan T. Deland, Ricardo Villar, Elizabeth A. Cody
article en
1 citations

Abstract

In this study of stemmed TAA implants, surgeons achieved alignment generally consistent with PSI predictions. PSI adequately predicted implant size. For most cases, PSI achieved similar alignment and correction of deformity compared with standard instrumentation. PSI did not improve radiographic alignment compared with traditional instrumentation and was associated with longer operative times, possibly reflecting the primary surgeon's early experience with the technique. Each surgeon should select PSI or the standard jig based on their experience and preference.

Foot & Ankle InternationalVol. 46(11)
Hospital for Special Surgery (US), University of Louisville (US), Cornell University (US)
Good health and well-being
Openalex Percentile: Top 16%
Foot and Ankle Surgery
1.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Patient-Specific Instrumentation Does Not Improve Alignment Compared to the Extramedullary Foot Holder for the INBONE II Total Ankle Arthroplasty — Charlotte H. Jones, Allison L. Boden, et al. · Foot & Ankle International (2025) | TGRS Research Map | TGRS