Novel Control Scheme to Reduce THD in Bidirectional Three‐Phase Inverter Using a Three‐Phase Unfolder for the Grid Forming Operation

ABSTRACT Recent trends emphasise the significance of bidirectional power conversion systems in grid‐forming operations. Minimising total harmonic distortion (THD) in these systems is crucial for enhancing power quality, efficiency and equipment lifespan. This study proposes a novel reference signal modification control scheme to reduce THD in a bidirectional inverter by adjusting the DC‐Link Voltage reference based on AC load feedback. Comparative analysis with conventional systems across various load types demonstrates superior performance, particularly with induction machine loads. The proposed control model involves multiple stages, including error computation, averaging, dynamic error handling, reference modification and regulation using a PI control block. This approach effectively manages error dynamics in the inverter topology and eliminates electromagnetic interference in the PCB without determining any additional theoretical approach. Both simulated and experimental results validate the theoretical analyses, showcasing the efficacy of the proposed method. Its simplicity in modifying the reference voltage makes it suitable for situations where controllers lack the capability to effectively manage desired outputs.

Authors

Institutions

Publication Details

Journal
IET Power Electronics
Published
2025-01-01
DOI
https://doi.org/10.1049/pel2.70087
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Control Scheme to Reduce THD in Bidirectional Three‐Phase Inverter Using a Three‐Phase Unfolder for the Grid Forming Operation

Mehmet Çelebi, Davut Ertekin
IET Power Electronics
Multilevel Inverters and Converters
article

Novel Control Scheme to Reduce THD in Bidirectional Three‐Phase Inverter Using a Three‐Phase Unfolder for the Grid Forming Operation

Mehmet Çelebi, Davut Ertekin
article en

Abstract

ABSTRACT Recent trends emphasise the significance of bidirectional power conversion systems in grid‐forming operations. Minimising total harmonic distortion (THD) in these systems is crucial for enhancing power quality, efficiency and equipment lifespan. This study proposes a novel reference signal modification control scheme to reduce THD in a bidirectional inverter by adjusting the DC‐Link Voltage reference based on AC load feedback. Comparative analysis with conventional systems across various load types demonstrates superior performance, particularly with induction machine loads. The proposed control model involves multiple stages, including error computation, averaging, dynamic error handling, reference modification and regulation using a PI control block. This approach effectively manages error dynamics in the inverter topology and eliminates electromagnetic interference in the PCB without determining any additional theoretical approach. Both simulated and experimental results validate the theoretical analyses, showcasing the efficacy of the proposed method. Its simplicity in modifying the reference voltage makes it suitable for situations where controllers lack the capability to effectively manage desired outputs.

IET Power ElectronicsVol. 18(1)
The University of Western Australia (AU), Bursa Technical University (TR), Usak University (TR)
Openalex Percentile: Top 84%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.