Comparative Efficacy and Safety of 0.8‐L Versus 2‐L Polyethylene Glycol‐Ascorbic Acid Solutions in Colonoscopy Preparation: A Prospective, Multicenter, Randomized, Controlled Trial
The novel 0.8-L PEG-ascorbic acid solution was effective, safe, and highly tolerable, showing noninferiority to the 2-L PEG-ascorbic acid solution. The same-day regimen showed a tendency toward better cleansing efficacy in the ascending colon and higher patient satisfaction.
Authors
- Kwangwoo Nam (ORCID: https://orcid.org/0000-0003-3720-9820)
- Bomee Lee (ORCID: https://orcid.org/0009-0003-6519-4168)
- Hyun Gun Kim (ORCID: https://orcid.org/0000-0001-7545-4638)
- Min Seob Kwak (ORCID: https://orcid.org/0000-0002-8988-7423)
- Sung Noh Hong (ORCID: https://orcid.org/0000-0002-4140-3717)
- Soo‐Young Na (ORCID: https://orcid.org/0000-0003-3685-6823)
- Jong Pil Im (ORCID: https://orcid.org/0000-0003-1584-0160)
- Bora Keum (ORCID: https://orcid.org/0000-0003-0391-1945)
- Jeong‐Sik Byeon (ORCID: https://orcid.org/0000-0002-9793-6379)
Institutions
- Ulsan College (KR)
- Seoul National University (KR)
- Korea University (KR)
- Soonchunhyang University (KR)
- Korea University Medical Center (KR)
- Asan Medical Center (KR)
- Samsung Medical Center (KR)
- University of Ulsan (KR)
- The Catholic University of Korea Incheon St. Mary's Hospital (KR)
- Kyung Hee University Hospital at Gangdong (KR)
- Korea University (JP)
- Dankook University Hospital (KR)
- Sungkyunkwan University (KR)
- Catholic University of Korea (KR)
Publication Details
- Journal
- Journal of Gastroenterology and Hepatology
- Published
- 2025-07-24
- DOI
- https://doi.org/10.1111/jgh.70006
- Citations
- 4
- Primary Topic
- Colorectal Cancer Screening and Detection
- Type
- article
- Field-Weighted Citation Impact
- 4.18