A Hybrid Analog-Digital Circuit Framework for Enhanced Cycle-by-Cycle Fourier Series Analysis: Motion Artifact Mitigation in Photoplethysmography Signal Acquisition

Pulse oximeters need to collect light signals at red and infrared (IR) wavelengths to measure how much oxygen is in a patient's blood. Patient motion induces motion artifacts in PPG signals, introducing significant computational errors. Cycle-by-Cycle Fourier Series Analysis (CFSA) has been demonstrated as an effective method for eliminating motion artifact interference in Photoplethysmography (PPG) signals. This paper explores methods to obtain sufficiently accurate cycle periods to reduce CFSA result errors and proposes an approach combining high-pass filtering with differential amplifier circuitry for preprocessing raw PPG signals to enhance cycle period detection. The experimental results confirm the effectiveness of the proposed method, demonstrating that the Signal-to-Total Noise Band Ratio (SNBR_dB) of PPG signals was increased from 0.53 dB to 5.90 dB, while the linearity improved from 1.13 to 4.39. Furthermore, this study extends the utilization of analog integrated circuits for motion artifact mitigation in biomedical signal processing.

Authors

Institutions

Publication Details

Journal
Applied and Computational Engineering
Published
2025-07-24
DOI
https://doi.org/10.54254/2755-2721/2025.po25393
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Hybrid Analog-Digital Circuit Framework for Enhanced Cycle-by-Cycle Fourier Series Analysis: Motion Artifact Mitigation in Photoplethysmography Signal Acquisition

Siwei Li
Applied and Computational Engineering
Non-Invasive Vital Sign Monitoring
article

A Hybrid Analog-Digital Circuit Framework for Enhanced Cycle-by-Cycle Fourier Series Analysis: Motion Artifact Mitigation in Photoplethysmography Signal Acquisition

Siwei Li
article en

Abstract

Pulse oximeters need to collect light signals at red and infrared (IR) wavelengths to measure how much oxygen is in a patient's blood. Patient motion induces motion artifacts in PPG signals, introducing significant computational errors. Cycle-by-Cycle Fourier Series Analysis (CFSA) has been demonstrated as an effective method for eliminating motion artifact interference in Photoplethysmography (PPG) signals. This paper explores methods to obtain sufficiently accurate cycle periods to reduce CFSA result errors and proposes an approach combining high-pass filtering with differential amplifier circuitry for preprocessing raw PPG signals to enhance cycle period detection. The experimental results confirm the effectiveness of the proposed method, demonstrating that the Signal-to-Total Noise Band Ratio (SNBR_dB) of PPG signals was increased from 0.53 dB to 5.90 dB, while the linearity improved from 1.13 to 4.39. Furthermore, this study extends the utilization of analog integrated circuits for motion artifact mitigation in biomedical signal processing.

Applied and Computational EngineeringVol. 178(1)
Shanghai Jiao Tong University (CN)
Openalex Percentile: Top 83%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.