Pemeliharaan Tahunan Pressure Transmitter Area Steam Generation Industri Petrokimia di PT. X

Monitoring steam generation systems in the petrochemical industry is essential because small pressure changes can significantly affect product quality and pose safety risks. This study focuses on calibrating the Endress+Hauser Cerabar M PMC41 pressure Transmitter at PT. X, a leading Indonesian fatty alcohol and oleochemical producer. Calibration was performed to ensure accurate pressure measurement of steam generation processes using a zero calibration technique to correct reading Errors. Measurement data were collected before and after calibration at 0%, 25%, 50%, and 100% pressure levels. The initial Error in pressure measurement was 31.799 bar (4.47%), while the current output Error was 16.76 mA (3.8%). After calibration, these Errors reduced to 30.266 bar (0.72%) and 16.023 mA (0.115%), respectively. These results indicate a significant improvement in the Transmitter’s performance, aligning with the International Electrotechnical Commission (IEC) No. 13B-23 standards. The calibration process effectively minimized measurement Errors, ensuring precise monitoring of pressure parameters in the steam generation system and maintaining operational stability. Accurate pressure control is crucial to optimizing production efficiency and maintaining safety standards at PT. X.

Authors

Institutions

Publication Details

Journal
ELPOSYS Jurnal Sistem Kelistrikan
Published
2025-06-30
DOI
https://doi.org/10.33795/elposys.v12i2.6424
Primary Topic
Chemical and Environmental Engineering Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pemeliharaan Tahunan Pressure Transmitter Area Steam Generation Industri Petrokimia di PT. X

Munjar Hafiz, Novan Akhiriyanto
ELPOSYS Jurnal Sistem Kelistrikan
Chemical and Environmental Engineering Research
article

Pemeliharaan Tahunan Pressure Transmitter Area Steam Generation Industri Petrokimia di PT. X

Munjar Hafiz, Novan Akhiriyanto
article en

Abstract

Monitoring steam generation systems in the petrochemical industry is essential because small pressure changes can significantly affect product quality and pose safety risks. This study focuses on calibrating the Endress+Hauser Cerabar M PMC41 pressure Transmitter at PT. X, a leading Indonesian fatty alcohol and oleochemical producer. Calibration was performed to ensure accurate pressure measurement of steam generation processes using a zero calibration technique to correct reading Errors. Measurement data were collected before and after calibration at 0%, 25%, 50%, and 100% pressure levels. The initial Error in pressure measurement was 31.799 bar (4.47%), while the current output Error was 16.76 mA (3.8%). After calibration, these Errors reduced to 30.266 bar (0.72%) and 16.023 mA (0.115%), respectively. These results indicate a significant improvement in the Transmitter’s performance, aligning with the International Electrotechnical Commission (IEC) No. 13B-23 standards. The calibration process effectively minimized measurement Errors, ensuring precise monitoring of pressure parameters in the steam generation system and maintaining operational stability. Accurate pressure control is crucial to optimizing production efficiency and maintaining safety standards at PT. X.

ELPOSYS Jurnal Sistem KelistrikanVol. 12(2)
Politeknik Energi dan Mineral Akamigas
Openalex Percentile: Top 73%
Chemical and Environmental Engineering Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Pemeliharaan Tahunan Pressure Transmitter Area Steam Generation Industri Petrokimia di PT. X — Munjar Hafiz, Novan Akhiriyanto · ELPOSYS Jurnal Sistem Kelistrikan (2025) | TGRS Research Map | TGRS