Proteksi Arus Netral dan Suhu Transformator Berbasis IoT Dampak Beban Tidak Seimbang

Current imbalance results in neutral current and an increase in the temperature of the distribution transformer body. Due to the large number and scattered locations, maintenance of the transformers is carried out at least three times a year. Therefore, the authors developed a laboratory-scale device, which is a miniature neutral current and temperature increase protection system based on the Internet of Things (IoT). The results from the laboratory-scale testing of this protection system will disconnect the load when the current imbalance reaches ≥25% and the body temperature reaches ≥90˚C. Notifications will be sent to Telegram if the load current imbalance is in the range of 10%-14% (sufficient), 15%-24% (insufficient), and ≥25% (poor), and temperatures of 83-84℃ (sufficient), 85-89℃ (insufficient), and ≥90℃ (poor). The miniature protection can disconnect the load when the imbalance value is 25.92% and the temperature reaches 90˚C. Monitoring data is stored in a logger and can be downloaded. Thus, this tool can enhance reliability and help PLN personnel work more effectively.

Authors

Institutions

Publication Details

Journal
ELPOSYS Jurnal Sistem Kelistrikan
Published
2025-06-30
DOI
https://doi.org/10.33795/elposys.v12i2.6207
Primary Topic
Engineering and Technology Innovations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proteksi Arus Netral dan Suhu Transformator Berbasis IoT Dampak Beban Tidak Seimbang

Suhariningsih Suhariningsih, Reynaldo Satrio Fischa Pratama, Indhana Sudiharto
ELPOSYS Jurnal Sistem Kelistrikan
Engineering and Technology Innovations
article

Proteksi Arus Netral dan Suhu Transformator Berbasis IoT Dampak Beban Tidak Seimbang

Suhariningsih Suhariningsih, Reynaldo Satrio Fischa Pratama, Indhana Sudiharto
article en

Abstract

Current imbalance results in neutral current and an increase in the temperature of the distribution transformer body. Due to the large number and scattered locations, maintenance of the transformers is carried out at least three times a year. Therefore, the authors developed a laboratory-scale device, which is a miniature neutral current and temperature increase protection system based on the Internet of Things (IoT). The results from the laboratory-scale testing of this protection system will disconnect the load when the current imbalance reaches ≥25% and the body temperature reaches ≥90˚C. Notifications will be sent to Telegram if the load current imbalance is in the range of 10%-14% (sufficient), 15%-24% (insufficient), and ≥25% (poor), and temperatures of 83-84℃ (sufficient), 85-89℃ (insufficient), and ≥90℃ (poor). The miniature protection can disconnect the load when the imbalance value is 25.92% and the temperature reaches 90˚C. Monitoring data is stored in a logger and can be downloaded. Thus, this tool can enhance reliability and help PLN personnel work more effectively.

ELPOSYS Jurnal Sistem KelistrikanVol. 12(2)
Politeknik Elektronika Negeri Surabaya
Openalex Percentile: Top 84%
Engineering and Technology Innovations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Proteksi Arus Netral dan Suhu Transformator Berbasis IoT Dampak Beban Tidak Seimbang — Suhariningsih Suhariningsih, Reynaldo Satrio Fischa Pratama, et al. · ELPOSYS Jurnal Sistem Kelistrikan (2025) | TGRS Research Map | TGRS