Plating Nikel pada Kawat Tembaga untuk Meningkatkan Kepekaan sebagai Sensor Suhu Rendah

This research aims to determine the sensitivity of the sensor as a low temperature sensor from the Ni-coated Cu coil with electroplating technique. The deposition parameters are set, namely the electrolyte solution by dissolving NiSO4, NiCl2, H3BO4 and distilled water, voltage 4.5V, electrode distance 4 cm, electrolyte temperature 60 ° C for 4 minutes. The sensor sensitivity test was carried out by varying the temperature from 0˚C to -150˚C by inserting the sensor in a liquid nitrogen thermos and lifting it to its original position. Acquisition of temperature and voltage data at any time was carried out with the help of a transducer. Based on the results of the study, the Voltage-Temperature curve shows that the sensitivity value obtained by the Cu coil is S(T) = -1E-06 T - 5E-05 and the Cu/Ni coil S(T) = -4E-06 T - 0.0002. The results of the T=-200 ˚C projection show that the sensitivity value of the Cu/Ni coil has a greater value than the Cu coil. The Cu coil shows a value of 0.00035 while the Cu/Ni coil is 0.0014. So Ni has an effect on increasing the sensitivity of the Cu coil as a low temperature sensor.

Authors

Institutions

Publication Details

Journal
JIPFRI (Jurnal Inovasi Pendidikan Fisika dan Riset Ilmiah)
Published
2025-06-07
DOI
https://doi.org/10.30599/jipfri.v9i1.3402
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Plating Nikel pada Kawat Tembaga untuk Meningkatkan Kepekaan sebagai Sensor Suhu Rendah

Siti Zahra Helmalia Putri Zahra, Moh. Toifur
JIPFRI (Jurnal Inovasi Pendidikan Fisika dan Riset Ilmiah)
Sensor Technology and Measurement Systems
article

Plating Nikel pada Kawat Tembaga untuk Meningkatkan Kepekaan sebagai Sensor Suhu Rendah

Siti Zahra Helmalia Putri Zahra, Moh. Toifur
article en

Abstract

This research aims to determine the sensitivity of the sensor as a low temperature sensor from the Ni-coated Cu coil with electroplating technique. The deposition parameters are set, namely the electrolyte solution by dissolving NiSO4, NiCl2, H3BO4 and distilled water, voltage 4.5V, electrode distance 4 cm, electrolyte temperature 60 ° C for 4 minutes. The sensor sensitivity test was carried out by varying the temperature from 0˚C to -150˚C by inserting the sensor in a liquid nitrogen thermos and lifting it to its original position. Acquisition of temperature and voltage data at any time was carried out with the help of a transducer. Based on the results of the study, the Voltage-Temperature curve shows that the sensitivity value obtained by the Cu coil is S(T) = -1E-06 T - 5E-05 and the Cu/Ni coil S(T) = -4E-06 T - 0.0002. The results of the T=-200 ˚C projection show that the sensitivity value of the Cu/Ni coil has a greater value than the Cu coil. The Cu coil shows a value of 0.00035 while the Cu/Ni coil is 0.0014. So Ni has an effect on increasing the sensitivity of the Cu coil as a low temperature sensor.

JIPFRI (Jurnal Inovasi Pendidikan Fisika dan Riset Ilmiah)Vol. 9(1)
Universitas Ahmad Dahlan (ID)
Openalex Percentile: Top 80%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.