A comparison of image quality between digital and analog pet for spatial resolution: A phantom study

Background:The positron emission tomography (PET) technology has undergone continuous innovation in recent years.New-technology digital PETs are silicon photomultiplier (SiPM) PET systems with digital readouts, which contribute to improved image resolution.This study aimed to compare the image quality of subcentimeter lesions of NEMA PET phantom images obtained under identical imaging conditions (identical lesion volumes, identical activity and identical scanning time) using dPET, analog PET-1 and analog PET-2 acquired in the clinic.Materials and Methods: For image analysis, a standard NEMA IEC body phantom was used.In the present study, the lesion detection performance of all PETs was evaluated in two categories, sub-and over-centimeter size.The imaging durations of this study were 1, 2, 3, and 5 minutes, while the injection doses were 2.33 and 5.33 kBq/ml for the 1/4 and 1/8 background-to-lesion ratios, respectively.For a quantitative assessment of image quality, a circular ROI with activity concentrations (ACmean) and the mean recovery coefficient were calculated for each lesion via the ACmean.Results: Our study revealed approximately 15% greater RCmean values for dPET with SiPM technology compared to the analog PET-2 with PMT technology.However, analog PET-1 exhibited a significant lack of performance, especially when compared to analog PET -2 and dPET.Conclusion: Although dPET, the first generation of dPETs analyzed in the present study, yields relatively better RCmean values than analog PETs, it is not able to entirely eliminate the unfavorable impacts of PVE for sub-centimeter lesions.

Authors

Institutions

Publication Details

Journal
International Journal of Radiation Research
Published
2025-05-01
DOI
https://doi.org/10.61186/ijrr.23.2.19
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A comparison of image quality between digital and analog pet for spatial resolution: A phantom study

M Doyuran, Mustafa Çağlar, Savaş Karyağar, Tuğrul Çakır et al.
International Journal of Radiation Research
Advanced X-ray and CT Imaging
article

A comparison of image quality between digital and analog pet for spatial resolution: A phantom study

M Doyuran, Mustafa Çağlar, Savaş Karyağar, Tuğrul Çakır, Müjdegül Zayıfoğlu Karaca
article en

Abstract

Background:The positron emission tomography (PET) technology has undergone continuous innovation in recent years.New-technology digital PETs are silicon photomultiplier (SiPM) PET systems with digital readouts, which contribute to improved image resolution.This study aimed to compare the image quality of subcentimeter lesions of NEMA PET phantom images obtained under identical imaging conditions (identical lesion volumes, identical activity and identical scanning time) using dPET, analog PET-1 and analog PET-2 acquired in the clinic.Materials and Methods: For image analysis, a standard NEMA IEC body phantom was used.In the present study, the lesion detection performance of all PETs was evaluated in two categories, sub-and over-centimeter size.The imaging durations of this study were 1, 2, 3, and 5 minutes, while the injection doses were 2.33 and 5.33 kBq/ml for the 1/4 and 1/8 background-to-lesion ratios, respectively.For a quantitative assessment of image quality, a circular ROI with activity concentrations (ACmean) and the mean recovery coefficient were calculated for each lesion via the ACmean.Results: Our study revealed approximately 15% greater RCmean values for dPET with SiPM technology compared to the analog PET-2 with PMT technology.However, analog PET-1 exhibited a significant lack of performance, especially when compared to analog PET -2 and dPET.Conclusion: Although dPET, the first generation of dPETs analyzed in the present study, yields relatively better RCmean values than analog PETs, it is not able to entirely eliminate the unfavorable impacts of PVE for sub-centimeter lesions.

International Journal of Radiation ResearchVol. 23(2)
Istanbul Medipol University (TR), Sağlık Bilimleri Üniversitesi (TR), University of Health Sciences Antigua (AG)
Openalex Percentile: Top 83%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A comparison of image quality between digital and analog pet for spatial resolution: A phantom study — M Doyuran, Mustafa Çağlar, et al. · International Journal of Radiation Research (2025) | TGRS Research Map | TGRS