Studi Faktor Kualitas Resonansi Bunyi pada Pipa Organa Tertutup Menggunakan Panjang Efektif

This study aims to improve the accuracy of resonance analysis in closed pipe resonance through the measurement of quality factor (Q) and effective air column length. The method employed involves an automated system based on Arduino, equipped with an HC-SR04 sensor to measure distance and a KY-037 sensor to detect sound amplitude, integrated with Python-based data analysis for determining the resonance frequency. The measurement results show that the use of effective length with tube radius correction and improved frequency determination methods can reduce error from 1.33% to 0.24%, as well as decrease the standard deviation from 0.45 cm to 0.37 cm. Furthermore, quality factor analysis indicates an increase in the average value from 20 to 31, suggesting that the implemented resonance system and analysis method provide more accurate results, despite increased variability. Overall, the system successfully delivers more precise measurements in the analysis of resonance characteristics in closed organ pipes, particularly in relation to energy dissipation.

Authors

Institutions

Publication Details

Journal
JIPFRI (Jurnal Inovasi Pendidikan Fisika dan Riset Ilmiah)
Published
2025-06-30
DOI
https://doi.org/10.30599/jipfri.v9i1.4186
Citations
2
Primary Topic
Sports and Physical Education Research
Type
article
Field-Weighted Citation Impact
9.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Studi Faktor Kualitas Resonansi Bunyi pada Pipa Organa Tertutup Menggunakan Panjang Efektif

Yudhiakto Pramudya, Feri Iskandar
2 citations
JIPFRI (Jurnal Inovasi Pendidikan Fisika dan Riset Ilmiah)
Sports and Physical Education Research
9.52
article

Studi Faktor Kualitas Resonansi Bunyi pada Pipa Organa Tertutup Menggunakan Panjang Efektif

Yudhiakto Pramudya, Feri Iskandar
article en
2 citations

Abstract

This study aims to improve the accuracy of resonance analysis in closed pipe resonance through the measurement of quality factor (Q) and effective air column length. The method employed involves an automated system based on Arduino, equipped with an HC-SR04 sensor to measure distance and a KY-037 sensor to detect sound amplitude, integrated with Python-based data analysis for determining the resonance frequency. The measurement results show that the use of effective length with tube radius correction and improved frequency determination methods can reduce error from 1.33% to 0.24%, as well as decrease the standard deviation from 0.45 cm to 0.37 cm. Furthermore, quality factor analysis indicates an increase in the average value from 20 to 31, suggesting that the implemented resonance system and analysis method provide more accurate results, despite increased variability. Overall, the system successfully delivers more precise measurements in the analysis of resonance characteristics in closed organ pipes, particularly in relation to energy dissipation.

JIPFRI (Jurnal Inovasi Pendidikan Fisika dan Riset Ilmiah)Vol. 9(1)
Universitas Ahmad Dahlan (ID)
Openalex Percentile: Top 3%
Sports and Physical Education Research
9.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Studi Faktor Kualitas Resonansi Bunyi pada Pipa Organa Tertutup Menggunakan Panjang Efektif — Yudhiakto Pramudya, Feri Iskandar · JIPFRI (Jurnal Inovasi Pendidikan Fisika dan Riset Ilmiah) (2025) | TGRS Research Map | TGRS