Zero and Ultra-Short Echo Time Sequences at 3-Tesla Can Accurately Depicts the Normal Anatomy of the Human Achilles Tendon Enthesis Organ in Vivo
<b>Background/Objectives</b>: Accurate visualization of the Achilles tendon enthesis is critical for distinguishing mechanical, degenerative, and inflammatory pathologies. Although ultrasonography is the first-line modality for suspected enthesis disease, recent technical advances may expand the role of magnetic resonance imaging (MRI). This study evaluated the utility of ultra-short echo time (UTE) and zero echo time (ZTE) sequences versus proton density-weighted imaging (PD-WI) for depicting the enthesis organ in healthy volunteers. <b>Methods:</b> In this institutional review board (IRB)-approved prospective single-center study, 50 asymptomatic adult volunteers underwent 3-Tesla hindfoot MRI with fat-suppressed PD-WI, UTE, and ZTE between 2018 and 2023. Four radiologists assessed image quality, signal-to-noise ratio, visibility, and abnormal high signal intensities (SIs) of the periost, sesamoid, and enthesis fibrocartilages (PCa, SCa, and ECa, respectively). Statistical tests included Chi-square, McNemar, paired Wilcoxon, and Benjamini-Hochberg adjustments for multiple comparisons. <b>Results</b>: The median age was 36 years (range: 20-51); 58% women were included. PD-WI and ZTE sequences were always available while UTE was unavailable in 24% of patients. PD-WI consistently failed to concomitantly visualize all fibrocartilages. ZTE and UTE visualized all fibrocartilages in 72% and 92.1% of volunteers, respectively, with significant differences favoring ZTE and UTE over PD-WI (<i>p</i> < 0.0001) and UTE over ZTE (<i>p</i> = 0.027). Inter-rater agreement exceeded 80% except for SCa on ZTE (68%, 95%CI: 53.2-80.1). Abnormal SCa findings in asymptomatic patients were more frequent with UTE (23.7%) and ZTE (34%) than with PD-WI (2%) (<i>p</i> = 0.0045). <b>Conclusions</b>: At 3-Tesla, UTE and ZTE sequences reliably depict the enthesis organ of the Achilles tendon, outperforming PD-WI. However, the high sensitivity of these sequences also presents challenges in interpretation.
Authors
- Nicolas Poursac
- Julie Poujol (ORCID: https://orcid.org/0009-0001-3720-378X)
- Paolo Spinnato (ORCID: https://orcid.org/0000-0001-6060-3215)
- Michael Carl (ORCID: https://orcid.org/0000-0002-9936-5813)
- Amandine Crombé (ORCID: https://orcid.org/0000-0003-0098-6482)
- B. Dallaudière (ORCID: https://orcid.org/0000-0001-9182-4168)
- Olivier Hauger
- Claire Fournier
- Marie-Camille Bohand
Institutions
- Centre National de la Recherche Scientifique (FR)
- Université de Bordeaux (FR)
- Inserm (FR)
- Centre de Résonance Magnétique des Systèmes Biologiques (FR)
- Bordeaux Population Health (FR)
- Clinique du Sport (FR)
- Hôpital Pellegrin (FR)
- Istituto Ortopedico Rizzoli (IT)
- BoRdeaux Institute of onCology (FR)
Publication Details
- Journal
- Journal of Clinical Medicine
- Published
- 2025-07-24
- DOI
- https://doi.org/10.3390/jcm14155251
- Primary Topic
- Tendon Structure and Treatment
- Type
- article
- Field-Weighted Citation Impact
- 0.00