Electromagnetic-thermal evaluation of different non-magnetic material configurations for power transformer tank cover

This study investigates the effectiveness of non-magnetic materials used in the cover plates of power and distribution transformers. In transformers with large nominal power ratings, the current flowing through the low voltage (LV) windings can reach values in the thousands of amperes. This substantial current generates a strong magnetic field within the transformer tank and cover plate. A common method to mitigate the associated ohmic losses, known as stray losses, is the application of magnetic shunts. However, due to the geometric complexity of the cover plate, the use of magnetic shunts is not feasible for this component. Alternatively, a practical approach to reduce stray losses and prevent overheating of the cover plate is the incorporation of non-magnetic materials between the LV bushings on the cover plate. It is important to note that the stray losses discussed here primarily arise from eddy currents induced in nearby metallic structures, not from ohmic losses within the LV windings themselves. This research proposes five different design scenarios involving non-magnetic segments, commonly used in transformer manufacturing, to be integrated into the cover plate. These scenarios are simulated and analyzed using the Finite Element Method (FEM). Both the ohmic losses induced by magnetic flux penetration in the cover plate and the resulting temperature distributions are thoroughly examined and compared across all cases. The findings demonstrate that the use of non-magnetic material segments significantly reduces stray losses and lowers the temperature of the cover plate. Among the proposed designs, the rectangular-shaped non-magnetic segment, positioned over the high-current region of the cover plate, exhibited the most favorable performance compared to the other configurations. • Power Transformer. • Energy Efficiency. • Transformer Stray Losses. • Transformer Cover Plate.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2025-07-24
DOI
https://doi.org/10.1016/j.rineng.2025.106352
Citations
4
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
2.92

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electromagnetic-thermal evaluation of different non-magnetic material configurations for power transformer tank cover

K. Kaplan, Selim Dikmen, Mohammad Hassan Hashemi, Farzad Ataei
4 citations
Results in Engineering
Power Transformer Diagnostics and Insulation
2.92
article

Electromagnetic-thermal evaluation of different non-magnetic material configurations for power transformer tank cover

K. Kaplan, Selim Dikmen, Mohammad Hassan Hashemi, Farzad Ataei
article en
4 citations

Abstract

This study investigates the effectiveness of non-magnetic materials used in the cover plates of power and distribution transformers. In transformers with large nominal power ratings, the current flowing through the low voltage (LV) windings can reach values in the thousands of amperes. This substantial current generates a strong magnetic field within the transformer tank and cover plate. A common method to mitigate the associated ohmic losses, known as stray losses, is the application of magnetic shunts. However, due to the geometric complexity of the cover plate, the use of magnetic shunts is not feasible for this component. Alternatively, a practical approach to reduce stray losses and prevent overheating of the cover plate is the incorporation of non-magnetic materials between the LV bushings on the cover plate. It is important to note that the stray losses discussed here primarily arise from eddy currents induced in nearby metallic structures, not from ohmic losses within the LV windings themselves. This research proposes five different design scenarios involving non-magnetic segments, commonly used in transformer manufacturing, to be integrated into the cover plate. These scenarios are simulated and analyzed using the Finite Element Method (FEM). Both the ohmic losses induced by magnetic flux penetration in the cover plate and the resulting temperature distributions are thoroughly examined and compared across all cases. The findings demonstrate that the use of non-magnetic material segments significantly reduces stray losses and lowers the temperature of the cover plate. Among the proposed designs, the rectangular-shaped non-magnetic segment, positioned over the high-current region of the cover plate, exhibited the most favorable performance compared to the other configurations. • Power Transformer. • Energy Efficiency. • Transformer Stray Losses. • Transformer Cover Plate.

Results in EngineeringVol. 27
Izmir University (TR)
Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Affordable and clean energy
Openalex Percentile: Top 9%
Power Transformer Diagnostics and Insulation
2.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.