Wearable Personal Uroflowmeter for Measuring Urine Leakage in Women with Incontinence: Feasibility Study

This paper describes a novel wearable personal uroflowmeter and its use to log urine leakage episodes in women. Consisting of a miniature flow rate sensor attached under the urethral meatus, it recorded both urine flow rate and volume during activities of daily living. The sensor communicated with a determining unit incorporating a microcontroller and an inertial measurement unit worn at the waist, facilitating the post-hoc determination of which activities and changes in pose caused leakage. Six women participated in a feasibility study performed in a clinical setting. The results indicate that the uroflowmeter was 97.5% accurate in assessing micturition flow compared to gold standard uroflowmetry and leakage measurements. The system also provides subject-specific information on the relationship between physical activity and urine leakage, thereby eliminating errors due to missing data and recall bias in bladder leakage diaries and circumventing the limitations of office-based uroflowmeters.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2025-07-24
DOI
https://doi.org/10.3390/bios15080481
Citations
2
Primary Topic
Pelvic floor disorders treatments
Type
article
Field-Weighted Citation Impact
3.34

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable Personal Uroflowmeter for Measuring Urine Leakage in Women with Incontinence: Feasibility Study

Faezeh Shanehsazzadeh, James A. Ashton‐Miller, Ali Attari, John O. L. DeLancey et al.
2 citations
Biosensors
Pelvic floor disorders treatments
3.34
article

Wearable Personal Uroflowmeter for Measuring Urine Leakage in Women with Incontinence: Feasibility Study

Faezeh Shanehsazzadeh, James A. Ashton‐Miller, Ali Attari, John O. L. DeLancey, Tana Kirkbride, Carol Day
article en
2 citations

Abstract

This paper describes a novel wearable personal uroflowmeter and its use to log urine leakage episodes in women. Consisting of a miniature flow rate sensor attached under the urethral meatus, it recorded both urine flow rate and volume during activities of daily living. The sensor communicated with a determining unit incorporating a microcontroller and an inertial measurement unit worn at the waist, facilitating the post-hoc determination of which activities and changes in pose caused leakage. Six women participated in a feasibility study performed in a clinical setting. The results indicate that the uroflowmeter was 97.5% accurate in assessing micturition flow compared to gold standard uroflowmetry and leakage measurements. The system also provides subject-specific information on the relationship between physical activity and urine leakage, thereby eliminating errors due to missing data and recall bias in bladder leakage diaries and circumventing the limitations of office-based uroflowmeters.

BiosensorsVol. 15(8)
University of Michigan (US), Procter & Gamble (United States) (US)
U.S. Public Health Service
Openalex Percentile: Top 8%
Pelvic floor disorders treatments
3.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.