Thermal Effects of Pulsed Infrared Lasers on Zirconia Implants at Different Temperatures In Vitro

<b>Objectives:</b> The aim of this study was to determine the differential temperature produced on ceramic implants using laser irradiation on a pulsed setting of intrabony defects in vitro. <b>Methods:</b> A ceramic (Zr) dental implant (Zeramex, 4.8 × 12 mm) was placed into a bovine bone block. A three-wall intrabony defect (6 × 4 × 3 mm) was created to mimic an osseous peri-implant defect. Thermocouples were placed on the apical and coronal areas to measure temperature changes (∆T) during 60 s of laser irradiation. The bovine block was heated to 37 °C, and the defect walls were irradiated with the CO<sub>2</sub> and Er,Cr:YSGG laser. The settings used were pulsed mode for both lasers, with 30 Hz and 1.5 W for the Er,Cr:YSGG laser and 70 Hz and 2 W for the CO<sub>2</sub> laser. The same laser settings were repeated at room temperature (RT, 23 °C). Twenty trials were performed for each experimental group at room and body temperature for assessment of ∆T. Paired t-test were used to compare the measurements between 37 °C and 23 °C for the Er,Cr:YSGG, and CO<sub>2</sub> laser, respectively. <b>Results:</b> The CO<sub>2</sub> laser resulted in the highest ∆T (°C) at the coronal (15.22 ± 0.28/8.82 ± 0.21) and apical (5.84 ± 0.14/2.30 ± 0.28) level when this laser was used in both room temperature and body temperature, respectively. The highest ∆T (°C) for the Er,Cr:YSGG laser at body temperature at the coronal thermocouple was 7.64 ± 0.55, while for the CO<sub>2</sub> laser, at body temperature was 8.82 ± 0.21. <b>Conclusion:</b> Within the limitations of our study, the use of CO<sub>2</sub> laser and Er,Cr:YSGG laser on peri-implant defects generally appears to be safe in treating peri-implant defects around zirconia implants in vitro.

Authors

Institutions

Publication Details

Journal
Dentistry Journal
Published
2025-07-24
DOI
https://doi.org/10.3390/dj13080342
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal Effects of Pulsed Infrared Lasers on Zirconia Implants at Different Temperatures In Vitro

Georgios E. Romanos, Joseph De Leon, Maryam Hafeez, George Kokkinos
Dentistry Journal
Dental Implant Techniques and Outcomes
article

Thermal Effects of Pulsed Infrared Lasers on Zirconia Implants at Different Temperatures In Vitro

Georgios E. Romanos, Joseph De Leon, Maryam Hafeez, George Kokkinos
article en

Abstract

<b>Objectives:</b> The aim of this study was to determine the differential temperature produced on ceramic implants using laser irradiation on a pulsed setting of intrabony defects in vitro. <b>Methods:</b> A ceramic (Zr) dental implant (Zeramex, 4.8 × 12 mm) was placed into a bovine bone block. A three-wall intrabony defect (6 × 4 × 3 mm) was created to mimic an osseous peri-implant defect. Thermocouples were placed on the apical and coronal areas to measure temperature changes (∆T) during 60 s of laser irradiation. The bovine block was heated to 37 °C, and the defect walls were irradiated with the CO<sub>2</sub> and Er,Cr:YSGG laser. The settings used were pulsed mode for both lasers, with 30 Hz and 1.5 W for the Er,Cr:YSGG laser and 70 Hz and 2 W for the CO<sub>2</sub> laser. The same laser settings were repeated at room temperature (RT, 23 °C). Twenty trials were performed for each experimental group at room and body temperature for assessment of ∆T. Paired t-test were used to compare the measurements between 37 °C and 23 °C for the Er,Cr:YSGG, and CO<sub>2</sub> laser, respectively. <b>Results:</b> The CO<sub>2</sub> laser resulted in the highest ∆T (°C) at the coronal (15.22 ± 0.28/8.82 ± 0.21) and apical (5.84 ± 0.14/2.30 ± 0.28) level when this laser was used in both room temperature and body temperature, respectively. The highest ∆T (°C) for the Er,Cr:YSGG laser at body temperature at the coronal thermocouple was 7.64 ± 0.55, while for the CO<sub>2</sub> laser, at body temperature was 8.82 ± 0.21. <b>Conclusion:</b> Within the limitations of our study, the use of CO<sub>2</sub> laser and Er,Cr:YSGG laser on peri-implant defects generally appears to be safe in treating peri-implant defects around zirconia implants in vitro.

Dentistry JournalVol. 13(8)
Stony Brook School (US)
Stony Brook University
Openalex Percentile: Top 74%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Thermal Effects of Pulsed Infrared Lasers on Zirconia Implants at Different Temperatures In Vitro — Georgios E. Romanos, Joseph De Leon, et al. · Dentistry Journal (2025) | TGRS Research Map | TGRS