Single-molecule localization microscopy error is sensor dependent and larger than theory predicts

Since the advent of stochastic localization microscopy approaches in 2006, the number of studies employing this strategy to investigate the subdiffraction limit features of fluorescently labeled structures in biology, biophysics and solid state samples has increased exponentially. Underpinning all these approaches is the notion that the position of single molecules can be determined to high precision, provided enough photons are collected. The determination of exactly how precisely, has been demanded to formulas that try to approximate the so-called Cramer-Rao lower bound based on input parameters such as the number of photons collected from the molecules, or the size of the camera pixel. These estimates should, however, be matched to the experimental localization precision, which can be easily determined if, instead of looking at single beads, we study the distance between a pair. We revisit here a few key works, observing how these theoretical determinations tend to routinely underestimate the experimental localization precision of the order of a factor 2. A software-independent metric to determine, based on each individual setup, the appropriate value to set on the localization error of individual emitters is provided.

Authors

Institutions

Publication Details

Journal
Biophysical Reports
Published
2025-07-24
DOI
https://doi.org/10.1016/j.bpr.2025.100223
Citations
1
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
1.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single-molecule localization microscopy error is sensor dependent and larger than theory predicts

Paolo Annibale, Alfonso Brenlla-Lopez, Laila Deen
1 citations
Biophysical Reports
Advanced Fluorescence Microscopy Techniques
1.63
article

Single-molecule localization microscopy error is sensor dependent and larger than theory predicts

Paolo Annibale, Alfonso Brenlla-Lopez, Laila Deen
article en
1 citations

Abstract

Since the advent of stochastic localization microscopy approaches in 2006, the number of studies employing this strategy to investigate the subdiffraction limit features of fluorescently labeled structures in biology, biophysics and solid state samples has increased exponentially. Underpinning all these approaches is the notion that the position of single molecules can be determined to high precision, provided enough photons are collected. The determination of exactly how precisely, has been demanded to formulas that try to approximate the so-called Cramer-Rao lower bound based on input parameters such as the number of photons collected from the molecules, or the size of the camera pixel. These estimates should, however, be matched to the experimental localization precision, which can be easily determined if, instead of looking at single beads, we study the distance between a pair. We revisit here a few key works, observing how these theoretical determinations tend to routinely underestimate the experimental localization precision of the order of a factor 2. A software-independent metric to determine, based on each individual setup, the appropriate value to set on the localization error of individual emitters is provided.

Biophysical ReportsVol. 5(3)
University of St Andrews (GB)
Openalex Percentile: Top 13%
Advanced Fluorescence Microscopy Techniques
1.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.