Microcatheter puff technique to improve understanding and outcome of aspiration thrombectomy: A technical video

Aspiration thrombectomy is an alternative to stent retriever thrombectomy that allows for faster thrombectomy passes with less cost.1 Despite advances in technology, rates of first-pass effect remain relatively low.1-3 Attempts are being made to improve understanding of aspiration forces and interactions which may benefit thrombectomy technique and future technologies. While information from in vivo studies is limited to pre-pass and post-pass angiograms, in vitro experiments allow for more careful measuring and understanding of these aspiration forces and interactions. These in vitro studies have generated conflicting data with unclear clinical application.4-9 To better glean information from thrombectomies in real-time and also to improve efficacy, a microcatheter 'puff' technique has been developed.10 This technique consists of gentle contrast puffs from a microcatheter within the aspiration catheter. Here in video 1, we demonstrate this technique and some of its benefits, illustrated by cases of large and medium vessel occlusion with primary aspiration thrombectomy.neurintsurg;jnis-2025-023890v1/V1F1V1Video 1 .

Authors

Institutions

Publication Details

Journal
Journal of NeuroInterventional Surgery
Published
2025-07-24
DOI
https://doi.org/10.1136/jnis-2025-023890
Primary Topic
Acute Ischemic Stroke Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microcatheter puff technique to improve understanding and outcome of aspiration thrombectomy: A technical video

Elliot Pressman, Sheyar Amin, Maxim Mokin
Journal of NeuroInterventional Surgery
Acute Ischemic Stroke Management
article

Microcatheter puff technique to improve understanding and outcome of aspiration thrombectomy: A technical video

Elliot Pressman, Sheyar Amin, Maxim Mokin
article en

Abstract

Aspiration thrombectomy is an alternative to stent retriever thrombectomy that allows for faster thrombectomy passes with less cost.1 Despite advances in technology, rates of first-pass effect remain relatively low.1-3 Attempts are being made to improve understanding of aspiration forces and interactions which may benefit thrombectomy technique and future technologies. While information from in vivo studies is limited to pre-pass and post-pass angiograms, in vitro experiments allow for more careful measuring and understanding of these aspiration forces and interactions. These in vitro studies have generated conflicting data with unclear clinical application.4-9 To better glean information from thrombectomies in real-time and also to improve efficacy, a microcatheter 'puff' technique has been developed.10 This technique consists of gentle contrast puffs from a microcatheter within the aspiration catheter. Here in video 1, we demonstrate this technique and some of its benefits, illustrated by cases of large and medium vessel occlusion with primary aspiration thrombectomy.neurintsurg;jnis-2025-023890v1/V1F1V1Video 1 .

Journal of NeuroInterventional Surgery
University of South Florida (US)
Openalex Percentile: Top 74%
Acute Ischemic Stroke Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Microcatheter puff technique to improve understanding and outcome of aspiration thrombectomy: A technical video — Elliot Pressman, Sheyar Amin, et al. · Journal of NeuroInterventional Surgery (2025) | TGRS Research Map | TGRS