Rotating cut magnetic sensor line-differential linear hall slightly weak magnetic field detector

This study was measured as the actual measurement value calculated through the coil and Hall components, and the weak magnetic field generated by the three coils with a voltage of 200 turns was measured. First of all, calculate the theoretical magnetic field value through the strength of the magnetic field source and the K value; then, the difference in the difference in calculation by detecting the difference between the actual magnetic field strength and theoretical value, and compare the difference in the difference with the theoretical value of the magnetic field. The error range is 3.03% - 5.56%. Because the distance between the measurement point and the magnetic field source is 14.32 cm, the magnetic field attenuation effect is available, which further derives a dynamic K value, and considers other influencing factors except R. This study provides effective methods and theoretical support for the measurement of a weak magnetic field.

Authors

Institutions

Publication Details

Published
2025-07-24
DOI
https://doi.org/10.1117/12.3068812
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rotating cut magnetic sensor line-differential linear hall slightly weak magnetic field detector

Zuanming Jin, 通雄 河野, Dan Tang, Yunlong Luan
Magnetic Field Sensors Techniques
article

Rotating cut magnetic sensor line-differential linear hall slightly weak magnetic field detector

Zuanming Jin, 通雄 河野, Dan Tang, Yunlong Luan
article en

Abstract

This study was measured as the actual measurement value calculated through the coil and Hall components, and the weak magnetic field generated by the three coils with a voltage of 200 turns was measured. First of all, calculate the theoretical magnetic field value through the strength of the magnetic field source and the K value; then, the difference in the difference in calculation by detecting the difference between the actual magnetic field strength and theoretical value, and compare the difference in the difference with the theoretical value of the magnetic field. The error range is 3.03% - 5.56%. Because the distance between the measurement point and the magnetic field source is 14.32 cm, the magnetic field attenuation effect is available, which further derives a dynamic K value, and considers other influencing factors except R. This study provides effective methods and theoretical support for the measurement of a weak magnetic field.

Liaoning Technical University (CN)
Affordable and clean energy
Openalex Percentile: Top 84%
Magnetic Field Sensors Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Rotating cut magnetic sensor line-differential linear hall slightly weak magnetic field detector — Zuanming Jin, 通雄 河野, et al. · (2025) | TGRS Research Map | TGRS