Monte Carlo investigation of dosimetry in shielded region in total body irradiation treatment

<i>Purpose</i>. Total body irradiation (TBI) is commonly used to treat hematological diseases requiring bone marrow transplantation. Partial transmission blocks (PTB) are utilized to shield critical organs such as the lungs and kidneys. Previous phantom measurement and convolution algorithms confirmed that the percent depth dose (PDD) under PTB deviates significantly from those regions without the PTB. In this study, we investigated the dosimetry under the PTB using the Monte Carlo tool and validated with measurement.<i>Methods</i>. The photon phase space (PSP) for Truebeam linac from MyVarian was used as input in the EGSnrc package. The PSP was analyzed and separated into primary point source photons (originating from the target) and extra-focal source photons (extra-focal source originating from flattening filter etc) components. It was hypothesized that they behave differently in the presence of PTB which is responsible for the uncommon dosimetry. A virtual filter module was developed to simulate the PTB of any transmission factors in EGSnrc. Further, a concept of Extra-focal Source Photon Enhancement Ratio (ESPER) was proposed to quantify how the extra-focal source photons' dose contribution changes with SSD, block size, block-to-patient distance, and transmission factor.<i>Results</i>. Extra-focal source photons accounts for 20% in 6X beam, but only 13% in 6XFFF. MC result of the virtual PTB filter agrees well with the measurement for PDD (<1.5%). For a clinical PTB of size 6 × 12 cm<sup>2</sup>at phantom surface, the ESPER at 5 cm depth increases from 1.34 to 2.38 when SSD 100 → 400 cm; decreases from 1.96 to 1.07 when block-surface-distance 149.7 → 10 cm; and decreases from 4.00 to 1.65 when PTB transmission factor 0 → 30%.<i>Conclusions</i>. The dosimetry under PTB for TBI can be explained by the different behavior of the primary point source and extra focal source photon components in phantom. This study provides valuable inputs on how to interpret the<i>in vivo</i>dose measurement under PTB.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2025-07-24
DOI
https://doi.org/10.1088/2057-1976/adf3b6
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monte Carlo investigation of dosimetry in shielded region in total body irradiation treatment

Qiuwen Wu, Peixiong Li, Xiaomin Liang
Biomedical Physics & Engineering Express
Advanced Radiotherapy Techniques
article

Monte Carlo investigation of dosimetry in shielded region in total body irradiation treatment

Qiuwen Wu, Peixiong Li, Xiaomin Liang
article en

Abstract

<i>Purpose</i>. Total body irradiation (TBI) is commonly used to treat hematological diseases requiring bone marrow transplantation. Partial transmission blocks (PTB) are utilized to shield critical organs such as the lungs and kidneys. Previous phantom measurement and convolution algorithms confirmed that the percent depth dose (PDD) under PTB deviates significantly from those regions without the PTB. In this study, we investigated the dosimetry under the PTB using the Monte Carlo tool and validated with measurement.<i>Methods</i>. The photon phase space (PSP) for Truebeam linac from MyVarian was used as input in the EGSnrc package. The PSP was analyzed and separated into primary point source photons (originating from the target) and extra-focal source photons (extra-focal source originating from flattening filter etc) components. It was hypothesized that they behave differently in the presence of PTB which is responsible for the uncommon dosimetry. A virtual filter module was developed to simulate the PTB of any transmission factors in EGSnrc. Further, a concept of Extra-focal Source Photon Enhancement Ratio (ESPER) was proposed to quantify how the extra-focal source photons' dose contribution changes with SSD, block size, block-to-patient distance, and transmission factor.<i>Results</i>. Extra-focal source photons accounts for 20% in 6X beam, but only 13% in 6XFFF. MC result of the virtual PTB filter agrees well with the measurement for PDD (<1.5%). For a clinical PTB of size 6 × 12 cm<sup>2</sup>at phantom surface, the ESPER at 5 cm depth increases from 1.34 to 2.38 when SSD 100 → 400 cm; decreases from 1.96 to 1.07 when block-surface-distance 149.7 → 10 cm; and decreases from 4.00 to 1.65 when PTB transmission factor 0 → 30%.<i>Conclusions</i>. The dosimetry under PTB for TBI can be explained by the different behavior of the primary point source and extra focal source photon components in phantom. This study provides valuable inputs on how to interpret the<i>in vivo</i>dose measurement under PTB.

Biomedical Physics & Engineering ExpressVol. 11(5)
Hong Kong Sanatorium and Hospital (HK), Duke Medical Center (US), Duke Kunshan University (CN)
Good health and well-being
Openalex Percentile: Top 76%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.