Research on the recognition method of secondary equipment misoperation for new power system

In order to reduce the probability of power accidents caused by relay protection equipment misoperation, this paper proposes a new type of secondary equipment misoperation identification method. Firstly, high-definition images of the operation state of secondary equipment are obtained through acquisition equipment, and kernel principal component analysis, phase correlation algorithm, and improved scale-invariant feature transformation are used to complete the denoising, fusion and feature extraction of the images. Secondly, according to the feature extraction results, convolutional neural network is used to realize misoperation state recognition. The experimental results show that the false detection rate of this method is less than 1.8%, while the leakage rate is less than 0.2%, which can comprehensively monitor the misoperation of different types of secondary equipment.

Authors

Institutions

Publication Details

Published
2025-05-23
DOI
https://doi.org/10.1109/icetci64844.2025.11084155
Primary Topic
Smart Grid and Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the recognition method of secondary equipment misoperation for new power system

Yanjing Zhang, Liang Guo, Wanru Wang, Dongbin Yu et al.
Smart Grid and Power Systems
article

Research on the recognition method of secondary equipment misoperation for new power system

Yanjing Zhang, Liang Guo, Wanru Wang, Dongbin Yu, Jiajun Chen, Xiaohong Situ
article en

Abstract

In order to reduce the probability of power accidents caused by relay protection equipment misoperation, this paper proposes a new type of secondary equipment misoperation identification method. Firstly, high-definition images of the operation state of secondary equipment are obtained through acquisition equipment, and kernel principal component analysis, phase correlation algorithm, and improved scale-invariant feature transformation are used to complete the denoising, fusion and feature extraction of the images. Secondly, according to the feature extraction results, convolutional neural network is used to realize misoperation state recognition. The experimental results show that the false detection rate of this method is less than 1.8%, while the leakage rate is less than 0.2%, which can comprehensively monitor the misoperation of different types of secondary equipment.

China Southern Power Grid (China) (CN), Power Grid Corporation (India) (IN), Xuchang University (CN)
Affordable and clean energy
Openalex Percentile: Top 84%
Smart Grid and Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.