Deep-Learning-Driven High Spatial Resolution Attenuation Imaging for Ultrasound Tomography (AI-UT)

Ultrasonic attenuation can be used to characterize tissue properties of the human breast. Both quantitative ultrasound (QUS) and ultrasound tomography (USCT) can provide attenuation estimation. However, limitations have been identified for both approaches. In QUS, the generation of attenuation maps involves separating the whole image into different data blocks. The optimal size of the data block is around 15-30 pulse lengths, which dramatically decreases the spatial resolution for attenuation imaging. In USCT, the attenuation is often estimated with a full wave inversion (FWI) method, which is affected by background noise. To achieve a high-resolution attenuation image with low variance, a deep learning (DL)-based method was proposed. In the approach, RF data from 60 angle views from the QTI Breast Acoustic CT (BACT) scanner were acquired as the input and attenuation images as the output. To improve image quality for the DL method, the spatial correlation between speed of sound (SOS) and attenuation were used as a constraint in the model. The results indicated that by including the SOS structural information, the performance of the model was improved. With a higher spatial resolution attenuation image, further segmentation of the breast can be achieved. The structural information and actual attenuation values provided by DL-generated attenuation images were validated with the values from the literature and the SOS-based segmentation map. The information provided by DL-generated attenuation images can be used as an additional biomarker for breast cancer diagnosis.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Published
2025-07-24
DOI
https://doi.org/10.1109/tuffc.2025.3592578
Citations
1
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep-Learning-Driven High Spatial Resolution Attenuation Imaging for Ultrasound Tomography (AI-UT)

Michael L. Oelze, Mingrui Liu, Gregory J. Czarnota, Zhengchang Kou et al.
1 citations
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Advanced X-ray and CT Imaging
0.67
article

Deep-Learning-Driven High Spatial Resolution Attenuation Imaging for Ultrasound Tomography (AI-UT)

Michael L. Oelze, Mingrui Liu, Gregory J. Czarnota, Zhengchang Kou, James Wiskin
article en
1 citations

Abstract

Ultrasonic attenuation can be used to characterize tissue properties of the human breast. Both quantitative ultrasound (QUS) and ultrasound tomography (USCT) can provide attenuation estimation. However, limitations have been identified for both approaches. In QUS, the generation of attenuation maps involves separating the whole image into different data blocks. The optimal size of the data block is around 15-30 pulse lengths, which dramatically decreases the spatial resolution for attenuation imaging. In USCT, the attenuation is often estimated with a full wave inversion (FWI) method, which is affected by background noise. To achieve a high-resolution attenuation image with low variance, a deep learning (DL)-based method was proposed. In the approach, RF data from 60 angle views from the QTI Breast Acoustic CT (BACT) scanner were acquired as the input and attenuation images as the output. To improve image quality for the DL method, the spatial correlation between speed of sound (SOS) and attenuation were used as a constraint in the model. The results indicated that by including the SOS structural information, the performance of the model was improved. With a higher spatial resolution attenuation image, further segmentation of the breast can be achieved. The structural information and actual attenuation values provided by DL-generated attenuation images were validated with the values from the literature and the SOS-based segmentation map. The information provided by DL-generated attenuation images can be used as an additional biomarker for breast cancer diagnosis.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlVol. 72(9)
Sunnybrook Health Science Centre (CA), University of Illinois Urbana-Champaign (US), Illinois College (US), Health Sciences Centre (CA), QT Ultrasound (United States) (US), Marin Community Foundation (US)
National Institutes of Health
Openalex Percentile: Top 29%
Advanced X-ray and CT Imaging
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.