A Single-Ended Fault Location Method for DC Transmission Lines Based on Inverse Distance Weighted Interpolation

The accuracy and reliability of single-ended fault location methods are often affected by boundary elements and transition resistances. This paper proposes a single-ended fault location method for DC transmission lines based on the initial traveling wave dominant frequency (ITWDF) attenuation characteristics. Firstly, the attenuation characteristics of the initial traveling wave frequency component are analyzed, and the attenuation law and distribution differences between the frequency component and fault distance are revealed. Secondly, to accurately extract and describe the trend of the initial traveling wave frequency component with the change of fault distance, the energy of the initial traveling wave is constructed, and the mathematical expression of the ITWDF related to the fault distance and unit length distortion coefficient is obtained. Theoretical analysis verifies that the ITWDF exhibits a monotonic attenuation mapping relationship with increasing fault distance. In addition, the attenuation characteristics of the ITWDF are not affected by fault impedance. Finally, a fault sample set containing the ITWDF and reference unit length distortion coefficients at different positions is constructed. The fault location is calculated using the ITWDF and the reference unit length distortion coefficient, with continuous wavelet transform and inverse distance weighting interpolation algorithms applied, respectively. Simulation results show that the proposed method can reliably locate faults under high-impedance conditions of up to 800Ω, and the absolute error is less than 200m. Moreover, the proposed method can be applied to DC lines with various boundary structures, improving the reliability of single-ended fault location.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3591637
Citations
1
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
1.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Single-Ended Fault Location Method for DC Transmission Lines Based on Inverse Distance Weighted Interpolation

Tianle Li, Feng Deng, Xiaoyu Yang, Kaiyuan He et al.
1 citations
IEEE Access
Power Systems Fault Detection
1.21
article

A Single-Ended Fault Location Method for DC Transmission Lines Based on Inverse Distance Weighted Interpolation

Tianle Li, Feng Deng, Xiaoyu Yang, Kaiyuan He, Zhixiang Wang, Dongli Jia
article en
1 citations

Abstract

The accuracy and reliability of single-ended fault location methods are often affected by boundary elements and transition resistances. This paper proposes a single-ended fault location method for DC transmission lines based on the initial traveling wave dominant frequency (ITWDF) attenuation characteristics. Firstly, the attenuation characteristics of the initial traveling wave frequency component are analyzed, and the attenuation law and distribution differences between the frequency component and fault distance are revealed. Secondly, to accurately extract and describe the trend of the initial traveling wave frequency component with the change of fault distance, the energy of the initial traveling wave is constructed, and the mathematical expression of the ITWDF related to the fault distance and unit length distortion coefficient is obtained. Theoretical analysis verifies that the ITWDF exhibits a monotonic attenuation mapping relationship with increasing fault distance. In addition, the attenuation characteristics of the ITWDF are not affected by fault impedance. Finally, a fault sample set containing the ITWDF and reference unit length distortion coefficients at different positions is constructed. The fault location is calculated using the ITWDF and the reference unit length distortion coefficient, with continuous wavelet transform and inverse distance weighting interpolation algorithms applied, respectively. Simulation results show that the proposed method can reliably locate faults under high-impedance conditions of up to 800Ω, and the absolute error is less than 200m. Moreover, the proposed method can be applied to DC lines with various boundary structures, improving the reliability of single-ended fault location.

IEEE AccessVol. 13
North China Electric Power University (CN), China Power Engineering Consulting Group (China) (CN), Changsha University of Science and Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 19%
Power Systems Fault Detection
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.