Learned Discrepancy Reconstruction and Benchmark Dataset for Magnetic Particle Imaging

Magnetic Particle Imaging (MPI) is an emerging imaging modality based on the magnetic response of superparamagnetic iron oxide nanoparticles to achieve high-resolution and real-time imaging without harmful radiation. One key challenge in the MPI image reconstruction task arises from its underlying noise model, which does not fulfill the implicit Gaussian assumptions that are made when applying traditional reconstruction approaches. To address this challenge, we introduce the Learned Discrepancy Approach, a novel learning-based reconstruction method for inverse problems that includes a learned discrepancy function. It enhances traditional techniques by incorporating an invertible neural network to explicitly model problem-specific noise distributions. This approach does not rely on implicit Gaussian noise assumptions, making it especially suited to handle the sophisticated noise model in MPI and also applicable to other inverse problems. To further advance MPI reconstruction techniques, we introduce the MPI-MNIST dataset — a large collection of simulated MPI measurements derived from the MNIST dataset of handwritten digits. The dataset includes noise-perturbed measurements generated from state-of-the-art model-based system matrices and measurements of a preclinical MPI scanner device. This provides a realistic and flexible environment for algorithm testing. Validated against the MPI-MNIST dataset, our method demonstrates significant improvements in reconstruction quality in terms of structural similarity, achieving up to 7.9% higher SSIM as well as 2.2 dB higher PSNR compared to classical reconstruction techniques across varying noise levels, underscoring its robustness in high-noise scenarios.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Computational Imaging
Published
2025-01-01
DOI
https://doi.org/10.1109/tci.2025.3592335
Citations
2
Primary Topic
Characterization and Applications of Magnetic Nanoparticles
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Learned Discrepancy Reconstruction and Benchmark Dataset for Magnetic Particle Imaging

Hannes Albers, Tobias A. Knopp, Tobias Kluth, Meira Iske
2 citations
IEEE Transactions on Computational Imaging
Characterization and Applications of Magnetic Nanoparticles
1.35
article

Learned Discrepancy Reconstruction and Benchmark Dataset for Magnetic Particle Imaging

Hannes Albers, Tobias A. Knopp, Tobias Kluth, Meira Iske
article en
2 citations

Abstract

Magnetic Particle Imaging (MPI) is an emerging imaging modality based on the magnetic response of superparamagnetic iron oxide nanoparticles to achieve high-resolution and real-time imaging without harmful radiation. One key challenge in the MPI image reconstruction task arises from its underlying noise model, which does not fulfill the implicit Gaussian assumptions that are made when applying traditional reconstruction approaches. To address this challenge, we introduce the Learned Discrepancy Approach, a novel learning-based reconstruction method for inverse problems that includes a learned discrepancy function. It enhances traditional techniques by incorporating an invertible neural network to explicitly model problem-specific noise distributions. This approach does not rely on implicit Gaussian noise assumptions, making it especially suited to handle the sophisticated noise model in MPI and also applicable to other inverse problems. To further advance MPI reconstruction techniques, we introduce the MPI-MNIST dataset — a large collection of simulated MPI measurements derived from the MNIST dataset of handwritten digits. The dataset includes noise-perturbed measurements generated from state-of-the-art model-based system matrices and measurements of a preclinical MPI scanner device. This provides a realistic and flexible environment for algorithm testing. Validated against the MPI-MNIST dataset, our method demonstrates significant improvements in reconstruction quality in terms of structural similarity, achieving up to 7.9% higher SSIM as well as 2.2 dB higher PSNR compared to classical reconstruction techniques across varying noise levels, underscoring its robustness in high-noise scenarios.

IEEE Transactions on Computational ImagingVol. 11
Universität Hamburg (DE), University of Bremen (DE), University Medical Center Hamburg-Eppendorf (DE)
Openalex Percentile: Top 19%
Characterization and Applications of Magnetic Nanoparticles
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.