Strain measurement near the external fixation pin insertion site in an ankle joint fracture model using the digital image correlation method

This study aimed to construct an external fixation model using a cruciate technique that simulates muscle tension under resting and loading conditions during rehabilitation.This model serves as a foundational approach for evaluating the mechanical stability of human ankle joints through strain analysis.Additionally, the feasibility of visualizing strain near the fixation pin insertion site in the cruciate technique model was examined using stereo-DIC, with the goal of identifying mechanical indices for external fixation stability from an experimental mechanical perspective.External fixation often involves inserting the fixation pin obliquely into the bone surface, complicating the adjustment of the camera for accurate imaging.To address this challenge, we experimentally determined a measurement range that minimizes dependence on the stereo-DIC imaging direction.The results demonstrated successful visualization of the principal strain distribution near the fixation pin insertion site in the cruciate technique model using stereo-DIC.However, the maximum principal strain value was found to be influenced by the imaging direction.

Authors

Institutions

Publication Details

Journal
Journal of Advanced Science
Published
2025-01-01
DOI
https://doi.org/10.2978/jsas.37112
Primary Topic
Foot and Ankle Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Strain measurement near the external fixation pin insertion site in an ankle joint fracture model using the digital image correlation method

Ikuo Saito, K. Saigo, Hisao Kikugawa, Yuka Kobayashi et al.
Journal of Advanced Science
Foot and Ankle Surgery
article

Strain measurement near the external fixation pin insertion site in an ankle joint fracture model using the digital image correlation method

Ikuo Saito, K. Saigo, Hisao Kikugawa, Yuka Kobayashi, Y. Murayama
article en

Abstract

This study aimed to construct an external fixation model using a cruciate technique that simulates muscle tension under resting and loading conditions during rehabilitation.This model serves as a foundational approach for evaluating the mechanical stability of human ankle joints through strain analysis.Additionally, the feasibility of visualizing strain near the fixation pin insertion site in the cruciate technique model was examined using stereo-DIC, with the goal of identifying mechanical indices for external fixation stability from an experimental mechanical perspective.External fixation often involves inserting the fixation pin obliquely into the bone surface, complicating the adjustment of the camera for accurate imaging.To address this challenge, we experimentally determined a measurement range that minimizes dependence on the stereo-DIC imaging direction.The results demonstrated successful visualization of the principal strain distribution near the fixation pin insertion site in the cruciate technique model using stereo-DIC.However, the maximum principal strain value was found to be influenced by the imaging direction.

Journal of Advanced ScienceVol. 37(0)
Tokai University (JP), Tokai University Hachioji Hospital (JP), Tokai University Hospital (JP)
Openalex Percentile: Top 77%
Foot and Ankle Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.