Current Controllers for single-phase Grid-connected inverters: Review and Analysis

This paper mainly focuses on multiple current controller methods for a grid-connected inverter-based distributed generation. PI, PR, DQ, and Hysteresis controllers are the different control methods used for the analysis. Switching pulses for the conventional H-bridge inverter are generated, and the output total harmonic distortion analysis is performed using these controllers. Disadvantages of a PI current control include its steady-state errors as well as its extremely low rejection capability. As a solution to the issues of PI controller, PR controller was invented. In addition to the PI and PR controllers, Direct-Quadrature and hysteresis controllers are also studied and compared in terms of total harmonic distortion. Analytical results of the hysteresis current controller are compared with different bandwidths. The performance of these controllers has been examined using MATLAB/Simulink by evaluating the switching frequency and current THD of the inverter.

Authors

Publication Details

Journal
International Journal For Multidisciplinary Research
Published
2025-07-20
DOI
https://doi.org/10.36948/ijfmr.2025.v07i04.45075
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Current Controllers for single-phase Grid-connected inverters: Review and Analysis

P S Bhagyalakshmi, Bos Mathew Jos
International Journal For Multidisciplinary Research
Microgrid Control and Optimization
article

Current Controllers for single-phase Grid-connected inverters: Review and Analysis

P S Bhagyalakshmi, Bos Mathew Jos
article en

Abstract

This paper mainly focuses on multiple current controller methods for a grid-connected inverter-based distributed generation. PI, PR, DQ, and Hysteresis controllers are the different control methods used for the analysis. Switching pulses for the conventional H-bridge inverter are generated, and the output total harmonic distortion analysis is performed using these controllers. Disadvantages of a PI current control include its steady-state errors as well as its extremely low rejection capability. As a solution to the issues of PI controller, PR controller was invented. In addition to the PI and PR controllers, Direct-Quadrature and hysteresis controllers are also studied and compared in terms of total harmonic distortion. Analytical results of the hysteresis current controller are compared with different bandwidths. The performance of these controllers has been examined using MATLAB/Simulink by evaluating the switching frequency and current THD of the inverter.

International Journal For Multidisciplinary ResearchVol. 7(4)
Openalex Percentile: Top 79%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.