ESIPT-active fluorescent probes for ratiometric analysis of carbonate ions in aqueous media: structural modifications for enhanced selectivity and response

This study focuses on the design and synthesis of two ESIPT-active fluorescent probes that differ in the position of the hydroxyl group. The isomer with the hydroxyl group at the <i>ortho</i> position in compound 1 exhibited a large population of the keto tautomer in equilibrium, forming more compact nanoaggregates in aqueous media. In contrast, the enol form was predominant in compound 2, which has the hydroxyl group at the terminal position, leading to significantly larger aggregate sizes compared to the first probe. Both compounds demonstrated a ratiometric color-changing response with carbonate ions, accompanied by a turn-on fluorescence response. Mechanistic studies revealed that hydrogen bonding (or possible deprotonation) induced by carbonate ions influenced the keto-enol equilibrium and conformational flexibility, which affected both the optical properties and aggregation behavior of the probes. Comparative analysis showed that compound 1 had a superior response towards carbonate ions compared to probe 2. The position of the hydroxyl group altered the binding cleft available for carbonate ions. Furthermore, the naphthyl-substituted analogue of probe 1 formed larger aggregates and exhibited a stronger response to carbonate ions than probe 1 itself. Cross-reactivity studies confirmed the high selectivity of compound 1 for carbonate ions, with minimal interference from other anions. These results motivated the use of the current system for analyzing carbonate ions in natural water samples collected from the laboratory tap and nearby ponds. The high recovery rates and low standard deviation confirmed the suitability of this system for the quantitative analysis of carbonate in real-life samples.

Authors

Institutions

Publication Details

Journal
The Analyst
Published
2025-01-01
DOI
https://doi.org/10.1039/d5an00215j
Citations
2
Primary Topic
Molecular Sensors and Ion Detection
Type
article
Field-Weighted Citation Impact
1.51
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ESIPT-active fluorescent probes for ratiometric analysis of carbonate ions in aqueous media: structural modifications for enhanced selectivity and response

M. Gayathri, Nilanjan Dey, Sourav Mondal, Dharmarajan Sriram
2 citations
The Analyst
Molecular Sensors and Ion Detection
1.51
article

ESIPT-active fluorescent probes for ratiometric analysis of carbonate ions in aqueous media: structural modifications for enhanced selectivity and response

M. Gayathri, Nilanjan Dey, Sourav Mondal, Dharmarajan Sriram
article en
2 citations

Abstract

This study focuses on the design and synthesis of two ESIPT-active fluorescent probes that differ in the position of the hydroxyl group. The isomer with the hydroxyl group at the <i>ortho</i> position in compound 1 exhibited a large population of the keto tautomer in equilibrium, forming more compact nanoaggregates in aqueous media. In contrast, the enol form was predominant in compound 2, which has the hydroxyl group at the terminal position, leading to significantly larger aggregate sizes compared to the first probe. Both compounds demonstrated a ratiometric color-changing response with carbonate ions, accompanied by a turn-on fluorescence response. Mechanistic studies revealed that hydrogen bonding (or possible deprotonation) induced by carbonate ions influenced the keto-enol equilibrium and conformational flexibility, which affected both the optical properties and aggregation behavior of the probes. Comparative analysis showed that compound 1 had a superior response towards carbonate ions compared to probe 2. The position of the hydroxyl group altered the binding cleft available for carbonate ions. Furthermore, the naphthyl-substituted analogue of probe 1 formed larger aggregates and exhibited a stronger response to carbonate ions than probe 1 itself. Cross-reactivity studies confirmed the high selectivity of compound 1 for carbonate ions, with minimal interference from other anions. These results motivated the use of the current system for analyzing carbonate ions in natural water samples collected from the laboratory tap and nearby ponds. The high recovery rates and low standard deviation confirmed the suitability of this system for the quantitative analysis of carbonate in real-life samples.

The AnalystVol. 150(17)
Birla Institute of Technology and Science - Hyderabad Campus (IN)
Clean water and sanitation
Openalex Percentile: Top 17%
Molecular Sensors and Ion Detection
1.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.