A modified nearest level control scheme for a double star chopper cell modular multilevel converter for operation at lower values of amplitude modulation index

This paper presents a modified nearest level control (NLC) technique for a double star chopper cell modular multilevel converter (MMC). There are two prominent NLC techniques available in the literature for the MMC, one where the rounding off is done between 0.5 levels, and the other where the rounding off is done between 0.25 levels. However, both of them suffer from a serious drawback that they are unable to generate an output voltage at lower values of the modulation index. This paper presents a modified NLC technique that is capable of generating a satisfactory output voltage for lower values of modulation index while maintaining an acceptable total harmonic distortion in the output voltage waveform where the conventional NLC techniques fail to do so. Simulation results for an MMC with four submodules per arm are presented to verify the proposed modified NLC technique.

Authors

Institutions

Publication Details

Journal
International Journal of Power Electronics
Published
2025-01-01
DOI
https://doi.org/10.1504/ijpelec.2025.147360
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A modified nearest level control scheme for a double star chopper cell modular multilevel converter for operation at lower values of amplitude modulation index

Rana Das, Irfan Ahmed
International Journal of Power Electronics
HVDC Systems and Fault Protection
article

A modified nearest level control scheme for a double star chopper cell modular multilevel converter for operation at lower values of amplitude modulation index

Rana Das, Irfan Ahmed
article en

Abstract

This paper presents a modified nearest level control (NLC) technique for a double star chopper cell modular multilevel converter (MMC). There are two prominent NLC techniques available in the literature for the MMC, one where the rounding off is done between 0.5 levels, and the other where the rounding off is done between 0.25 levels. However, both of them suffer from a serious drawback that they are unable to generate an output voltage at lower values of the modulation index. This paper presents a modified NLC technique that is capable of generating a satisfactory output voltage for lower values of modulation index while maintaining an acceptable total harmonic distortion in the output voltage waveform where the conventional NLC techniques fail to do so. Simulation results for an MMC with four submodules per arm are presented to verify the proposed modified NLC technique.

International Journal of Power ElectronicsVol. 21(4)
National Institute of Technology Durgapur (IN)
Affordable and clean energy
Openalex Percentile: Top 84%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A modified nearest level control scheme for a double star chopper cell modular multilevel converter for operation at lower values of amplitude modulation index — Rana Das, Irfan Ahmed · International Journal of Power Electronics (2025) | TGRS Research Map | TGRS