Utility of an <i>in vitro</i> lymphatics on-chip model for rank ordering subcutaneous absorption of monoclonal antibodies

The lymphatic vasculature plays a key role in the subcutaneous absorption of macromolecules (>16 kDa). Recent trends toward subcutaneous delivery of macromolecular therapeutics have brought awareness to the need for preclinical estimation of subcutaneous bioavailability prior to first-in-human studies. <i>In vitro</i> tools offer a low-cost means to inform molecule design and formulation and mitigate costly mistakes of under- or overestimation of therapeutic dose and exposure in clinical studies. Building on a previous engineered on-chip lymphatics platform, the utility of an <i>in vitro</i> model to rank therapeutic proteins based on lymphatic absorption was investigated. Lymphatics grown under a combination of interstitial flow and growth factor supplementation on-chip demonstrated <i>in vivo</i>-like morphology, phenotypic marker expression, and solute drainage rates after a 4-day culture period. Dextrans of increasing molecular weight were assessed on the model and demonstrated an inverse relationship between size and diffusion coefficient. Similarly, a reduced lymphatic transport on-chip was observed for large antibody aggregates compared to non-aggregated molecules. More importantly, lymphatic transport of a panel of nine therapeutic proteins and monoclonal antibodies successfully rank ordered these molecules based on their subcutaneous bioavailability in humans (Pearson <i>r</i> = 0.8929). The on-chip lymphatics model described here appears as a promising tool for rank ordering subcutaneous lymphatic absorption during early drug development to increase the potential for successful candidate selection moving toward the clinic.

Authors

Institutions

Publication Details

Journal
Lab on a Chip
Published
2025-01-01
DOI
https://doi.org/10.1039/d4lc00988f
Citations
5
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
3.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Utility of an in vitro lymphatics on-chip model for rank ordering subcutaneous absorption of monoclonal antibodies

William R. Tschantz, Gerard Bruin, Karoline Bechtold-Peters, Ryan M. Pelis et al.
5 citations
Lab on a Chip
Microfluidic and Bio-sensing Technologies
3.37
article

Utility of an in vitro lymphatics on-chip model for rank ordering subcutaneous absorption of monoclonal antibodies

William R. Tschantz, Gerard Bruin, Karoline Bechtold-Peters, Ryan M. Pelis, Seunggyu Kim, J. van den Handel, Adriana M. Ledo, Thomas Dimke, Sujal V. Deshmukh, Manuel Sánchez-Félix, Maria Proestaki, Roger D. Kamm, Gabriela Misiewicz
article en
5 citations

Abstract

The lymphatic vasculature plays a key role in the subcutaneous absorption of macromolecules (>16 kDa). Recent trends toward subcutaneous delivery of macromolecular therapeutics have brought awareness to the need for preclinical estimation of subcutaneous bioavailability prior to first-in-human studies. <i>In vitro</i> tools offer a low-cost means to inform molecule design and formulation and mitigate costly mistakes of under- or overestimation of therapeutic dose and exposure in clinical studies. Building on a previous engineered on-chip lymphatics platform, the utility of an <i>in vitro</i> model to rank therapeutic proteins based on lymphatic absorption was investigated. Lymphatics grown under a combination of interstitial flow and growth factor supplementation on-chip demonstrated <i>in vivo</i>-like morphology, phenotypic marker expression, and solute drainage rates after a 4-day culture period. Dextrans of increasing molecular weight were assessed on the model and demonstrated an inverse relationship between size and diffusion coefficient. Similarly, a reduced lymphatic transport on-chip was observed for large antibody aggregates compared to non-aggregated molecules. More importantly, lymphatic transport of a panel of nine therapeutic proteins and monoclonal antibodies successfully rank ordered these molecules based on their subcutaneous bioavailability in humans (Pearson <i>r</i> = 0.8929). The on-chip lymphatics model described here appears as a promising tool for rank ordering subcutaneous lymphatic absorption during early drug development to increase the potential for successful candidate selection moving toward the clinic.

Lab on a ChipVol. 25(18)
Novartis (Switzerland) (CH), Novartis (United States) (US), US Biologic (United States) (US), Massachusetts Institute of Technology (US)
Good health and well-being
Openalex Percentile: Top 8%
Microfluidic and Bio-sensing Technologies
3.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.