SENSITIVITY OF BIOLUMINESCENCE METHOD FOR DETERMINING RESIDUAL QUANTITIES OF ANTIBIOTICS IN MINCED MEAT

Considering the significant costs of testing each package of minced meat, random monitoring becomes a practical and effective solution to the problem of quality control and food safety. The use of highly sensitive biosensor technologies can significantly speed up and improve the security monitoring process, allowing potential threats to be identified in the shortest possible time. The article demonstrates the sensitivity of the method in the analysis of residual quantities of various antibiotics: using the Antimicrobial Array I Ultra test kit - from 0,0005 to 0,002 mg/kg and Antimicrobial Array II Plus - from 0,0005 to 0,002 mg/kg depending on the analyte being determined. Such high sensitivity allows using this method in accordance with the amendment introduced to TR CU 021/2011 (application 51) for the determination of antibiotics and their permissible levels for meat products.

Authors

Publication Details

Journal
Problems of Veterinary Sanitation Hygiene and Ecology
Published
2025-01-01
DOI
https://doi.org/10.36871/vet.san.hyg.ecol.202502008
Primary Topic
bioluminescence and chemiluminescence research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SENSITIVITY OF BIOLUMINESCENCE METHOD FOR DETERMINING RESIDUAL QUANTITIES OF ANTIBIOTICS IN MINCED MEAT

Luiza.V. Arsenyeva, П. А. Попов, Е.А. Денисова, Veronica S. Babunova et al.
Problems of Veterinary Sanitation Hygiene and Ecology
bioluminescence and chemiluminescence research
article

SENSITIVITY OF BIOLUMINESCENCE METHOD FOR DETERMINING RESIDUAL QUANTITIES OF ANTIBIOTICS IN MINCED MEAT

Luiza.V. Arsenyeva, П. А. Попов, Е.А. Денисова, Veronica S. Babunova, Galina M. Goryainova
article en

Abstract

Considering the significant costs of testing each package of minced meat, random monitoring becomes a practical and effective solution to the problem of quality control and food safety. The use of highly sensitive biosensor technologies can significantly speed up and improve the security monitoring process, allowing potential threats to be identified in the shortest possible time. The article demonstrates the sensitivity of the method in the analysis of residual quantities of various antibiotics: using the Antimicrobial Array I Ultra test kit - from 0,0005 to 0,002 mg/kg and Antimicrobial Array II Plus - from 0,0005 to 0,002 mg/kg depending on the analyte being determined. Such high sensitivity allows using this method in accordance with the amendment introduced to TR CU 021/2011 (application 51) for the determination of antibiotics and their permissible levels for meat products.

Problems of Veterinary Sanitation Hygiene and EcologyVol. 2(54)
Openalex Percentile: Top 84%
bioluminescence and chemiluminescence research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

SENSITIVITY OF BIOLUMINESCENCE METHOD FOR DETERMINING RESIDUAL QUANTITIES OF ANTIBIOTICS IN MINCED MEAT — Luiza.V. Arsenyeva, П. А. Попов, et al. · Problems of Veterinary Sanitation Hygiene and Ecology (2025) | TGRS Research Map | TGRS