Comparative Biomechanical Analysis of Conventional and Sumo Deadlifts: Kinematics and Electromyography under Variable Load Conditions

This study compares the conventional and sumo deadlift techniques under different load conditions, integrating kinematic and electromyographic (EMG) analysis to identify biomechanical differences. The results show that the biceps femoris is the primary contributor to force production at an individual level, while the thoracolumbar fascia exhibits the greatest amplitude and power across participants. Kinematic analysis revealed that the conventional deadlift involves larger ranges of motion for the hip and back, increasing mechanical demands and stability requirements. Limitations, such as temporal offsets in EMG signals and sensor positioning errors, were identified, emphasizing the need for advanced tools to enhance accuracy. These findings provide insights to optimize training protocols, improve performance, and minimize injury risks.

Authors

Institutions

Publication Details

Published
2025-04-24
DOI
https://doi.org/10.1109/amathe65477.2025.11080740
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Biomechanical Analysis of Conventional and Sumo Deadlifts: Kinematics and Electromyography under Variable Load Conditions

Alexander Wöll, Victoria E. Abarca, J Moura, Aitor Palomino et al.
Orthopedic Surgery and Rehabilitation
article

Comparative Biomechanical Analysis of Conventional and Sumo Deadlifts: Kinematics and Electromyography under Variable Load Conditions

Alexander Wöll, Victoria E. Abarca, J Moura, Aitor Palomino, Diego A. Cuba
article en

Abstract

This study compares the conventional and sumo deadlift techniques under different load conditions, integrating kinematic and electromyographic (EMG) analysis to identify biomechanical differences. The results show that the biceps femoris is the primary contributor to force production at an individual level, while the thoracolumbar fascia exhibits the greatest amplitude and power across participants. Kinematic analysis revealed that the conventional deadlift involves larger ranges of motion for the hip and back, increasing mechanical demands and stability requirements. Limitations, such as temporal offsets in EMG signals and sensor positioning errors, were identified, emphasizing the need for advanced tools to enhance accuracy. These findings provide insights to optimize training protocols, improve performance, and minimize injury risks.

Facultad de Teología Pontificia y Civil de Lima (PE)
Openalex Percentile: Top 70%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative Biomechanical Analysis of Conventional and Sumo Deadlifts: Kinematics and Electromyography under Variable Load Conditions — Alexander Wöll, Victoria E. Abarca, et al. · (2025) | TGRS Research Map | TGRS