Differential Cortical Responses of Functional and Sensory Electrical Stimulation in Closed-Loop Tremor Suppression for Parkinson’s Disease

Functional electrical stimulation (FES) and sensory electrical stimulation (SES) are widely used in tremor suppression for Parkinson's disease (PD), however, their therapeutic efficacy varies significantly across individuals. This study investigated the differential cortical effects of FES and SES during closed-loop tremor suppression in PD patient, aiming to identify neurophysiological biomarkers for guiding personalized neuro modulation strategies. We developed an inertial based closed-loop tremor suppression system that delivers out-of-phase FES and continuous SES based on real-time tremor detection. Fifteen PD patients were recruited in tremor suppression trials while surface electroencephalography (EEG) and inertial-based movements of hand and forearm were measured. Both FES and SES significantly reduced tremor amplitude, with FES showing overall greater suppression (hand suppression rate: 60.72% vs. 48.31%, p >0.05; forearm suppression rate: 62.25% vs. 54.41%, p >0.05) where substantial inter-individual variability was observed. EEG analysis revealed that FES induced contralateral beta-band event-related desynchronization ( $\beta $ -ERD), whereas SES elicited beta-band event-related synchronization ( $\beta $ -ERS). These distinct cortical response patterns were significantly correlated with tremor suppression performance (FES $\beta $ -ERD: r = -0.629, p = 0.012; SES $\beta $ -ERS: r = 0.679, p = 0.005). Resting-state spectral analysis further revealed modality-specific changes in alpha power across sensorimotor regions. These findings revealed functional neurodynamic signatures associated with individual responsiveness to stimulation. The observed $\beta $ -band oscillatory responses may serve as candidate biomarkers for predicting individual treatment outcomes, offering a potentially biomarker-guided approach for personalized neuromodulation for PD tremor.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2025-01-01
DOI
https://doi.org/10.1109/tnsre.2025.3591134
Primary Topic
Neurological disorders and treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Differential Cortical Responses of Functional and Sensory Electrical Stimulation in Closed-Loop Tremor Suppression for Parkinson’s Disease

Xiaodong Zhu, Mengyue Jin, Lin Meng, Zhen Li et al.
1 links
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Neurological disorders and treatments
article

Differential Cortical Responses of Functional and Sensory Electrical Stimulation in Closed-Loop Tremor Suppression for Parkinson’s Disease

Xiaodong Zhu, Mengyue Jin, Lin Meng, Zhen Li, Yu Shi, Tao Huang, Xiaoqi Zhao, Hongbo Zhao, Qingqing Shi, Xiao Shen, Yanlin Wang
article en

Abstract

Functional electrical stimulation (FES) and sensory electrical stimulation (SES) are widely used in tremor suppression for Parkinson's disease (PD), however, their therapeutic efficacy varies significantly across individuals. This study investigated the differential cortical effects of FES and SES during closed-loop tremor suppression in PD patient, aiming to identify neurophysiological biomarkers for guiding personalized neuro modulation strategies. We developed an inertial based closed-loop tremor suppression system that delivers out-of-phase FES and continuous SES based on real-time tremor detection. Fifteen PD patients were recruited in tremor suppression trials while surface electroencephalography (EEG) and inertial-based movements of hand and forearm were measured. Both FES and SES significantly reduced tremor amplitude, with FES showing overall greater suppression (hand suppression rate: 60.72% vs. 48.31%, p >0.05; forearm suppression rate: 62.25% vs. 54.41%, p >0.05) where substantial inter-individual variability was observed. EEG analysis revealed that FES induced contralateral beta-band event-related desynchronization ( $\beta $ -ERD), whereas SES elicited beta-band event-related synchronization ( $\beta $ -ERS). These distinct cortical response patterns were significantly correlated with tremor suppression performance (FES $\beta $ -ERD: r = -0.629, p = 0.012; SES $\beta $ -ERS: r = 0.679, p = 0.005). Resting-state spectral analysis further revealed modality-specific changes in alpha power across sensorimotor regions. These findings revealed functional neurodynamic signatures associated with individual responsiveness to stimulation. The observed $\beta $ -band oscillatory responses may serve as candidate biomarkers for predicting individual treatment outcomes, offering a potentially biomarker-guided approach for personalized neuromodulation for PD tremor.

IEEE Transactions on Neural Systems and Rehabilitation EngineeringVol. 33
Tianjin University (CN), Tianjin Medical University General Hospital (CN), Tianjin Medical University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 73%
Neurological disorders and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Differential Cortical Responses of Functional and Sensory Electrical Stimulation in Closed-Loop Tremor Suppression for Parkinson’s Disease — Xiaodong Zhu, Mengyue Jin, et al. · IEEE Transactions on Neural Systems and Rehabilitation Engineering (2025) | TGRS Research Map | TGRS