Enhancing the Condensate Throttling Stability by Phase Lead Error-Based Active Disturbance Rejection Control Under Full Operating Conditions

Storage utilization can improve the frequency regulation of thermal power units. Condensate throttling is one of the most popular means, and the water level fluctuation brought by its process affects the unit operation safety. In this regard, a phase lead error-based active disturbance rejection control (PL-EADRC) that enhances the disturbance observation capability of conventional ADRC is designed. The condensate throttling with the PL-EADRC achieves a smooth change of load and suppresses the fluctuation of deaerator and condenser water levels. It shows that the proposed strategy has good disturbance rejection capability and robustness under full operating conditions. In addition, its simplicity of structure and ease of tuning mean that it has strong industrial utility.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Automation Science and Engineering
Published
2025-01-01
DOI
https://doi.org/10.1109/tase.2025.3591618
Citations
1
Primary Topic
Advanced Control Systems Optimization
Type
article
Field-Weighted Citation Impact
1.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing the Condensate Throttling Stability by Phase Lead Error-Based Active Disturbance Rejection Control Under Full Operating Conditions

Dawei Pang, Tianmu Qin, Ming Du, Yuguang Niu et al.
1 citations
IEEE Transactions on Automation Science and Engineering
Advanced Control Systems Optimization
1.21
article

Enhancing the Condensate Throttling Stability by Phase Lead Error-Based Active Disturbance Rejection Control Under Full Operating Conditions

Dawei Pang, Tianmu Qin, Ming Du, Yuguang Niu, Hengyi Zhu
article en
1 citations

Abstract

Storage utilization can improve the frequency regulation of thermal power units. Condensate throttling is one of the most popular means, and the water level fluctuation brought by its process affects the unit operation safety. In this regard, a phase lead error-based active disturbance rejection control (PL-EADRC) that enhances the disturbance observation capability of conventional ADRC is designed. The condensate throttling with the PL-EADRC achieves a smooth change of load and suppresses the fluctuation of deaerator and condenser water levels. It shows that the proposed strategy has good disturbance rejection capability and robustness under full operating conditions. In addition, its simplicity of structure and ease of tuning mean that it has strong industrial utility.

IEEE Transactions on Automation Science and EngineeringVol. 22
North China Electric Power University (CN)
National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 19%
Advanced Control Systems Optimization
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhancing the Condensate Throttling Stability by Phase Lead Error-Based Active Disturbance Rejection Control Under Full Operating Conditions — Dawei Pang, Tianmu Qin, et al. · IEEE Transactions on Automation Science and Engineering (2025) | TGRS Research Map | TGRS