Influence of gold and blue heat treatments on mechanical properties and phase transformation behavior of flat-designed rotary instruments
Objective: To evaluate the mechanical properties and austenite phase transformation temperature of flat-designed rotary instruments manufactured with gold and blue heat treatments. Material and Methods: A total of 60 rotary instruments with a flat design 25.04 with gold (Flat File 25.04 – MK Life, Brazil) and blue (Prototype 25.04 - MK Life, Brazil) heat treatments were used for cyclic fatigue, torsional fatigue, and bending tests (n=30). The cyclic fatigue test was conducted in an artificial canal with a curvature of 60° and a radius of 5 mm (n=10). The torsion test was conducted to evaluate the torque (N.cm) and angular deflection (°) required for fracture (n=10). Finally, the 60° bending test evaluated the force (g.f) required to flexion the instruments at the 5 mm tip (n=10). Differential Scanning Calorimetry (DSC) analysis was performed to establish the initial (Ai) and final (Af) austenitic transformation temperatures. The data were statistically analyzed using the Kolmogorov- Smirnov test for normality and the unpaired t-test, with a significance level of 5%. Results: The cyclic fatigue test showed that Flat 25.04 gold instruments had significantly greater cyclic fatigue resistance (p<0.05). The torsion test revealed that Flat 25.04 gold instruments exhibited lower maximum torque (N.cm) and greater angular deflection (°) (P<0.05). The bending test showed that the gold instrument required less force (P<0.05). DSC analysis demonstrated that the gold heat treatment had a higher Af temperature (42.8 °C) compared to the blue treatment (32.2 °C). Conclusion: The different heat treatments impacted in phase transformation temperatures and on the mechanical properties of the instruments. KEYWORDS Cyclic fatigue; Endodontics; Flat design; Nickel-Titanium; Torsional fatigue.
Authors
- Thaine Oliveira Lima (ORCID: https://orcid.org/0000-0001-5220-9947)
- Pablo Amoroso‐Silva (ORCID: https://orcid.org/0000-0001-5112-6162)
- Mônica Cristina Oliveira (ORCID: https://orcid.org/0000-0003-2594-9581)
- Murilo Priori Alcalde (ORCID: https://orcid.org/0000-0001-8735-065X)
- Rodrigo Ricci Vivan (ORCID: https://orcid.org/0000-0002-0419-5699)
- Marco Antônio Húngaro Duarte (ORCID: https://orcid.org/0000-0003-3051-737X)
- Ana Vieira (ORCID: https://orcid.org/0000-0003-3863-1070)
- Guilherme Ferreira da Silva (ORCID: https://orcid.org/0000-0002-8019-6714)
Institutions
- Universidade Estadual de Londrina (BR)
- Fundação Faculdade de Odontologia (BR)
Publication Details
- Journal
- Brazilian Dental Science
- Published
- 2025-01-01
- DOI
- https://doi.org/10.4322/bds.2025.e4638
- Primary Topic
- Advanced Measurement and Metrology Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00