CCEM key comparison CCEM.RF-K5c.CL

Main text An international measurement comparison, identified as CCEM.RF-K5c.CL, for scattering parameters and reflection coefficients by broad-band method was conducted between twenty national metrology institutes. The purpose of the comparison is to establish the calibration measurement capability of each participating laboratory. This report presents the key comparison reference values and degree of equivalence of each participant with respect to the key comparison reference values of the comparison. The participants measured seven travelling standards, an adapter, a 20 dB attenuator, a 40 dB attenuator, two matched terminations, and two flush short terminations with 3.5 mm coaxial connectors from 0.1 GHz to 33 GHz. The pilot laboratory is National Metrology Institute of Japan (NMIJ) and the supporting laboratories are Federal Institute of Metrology (METAS) and National Physical Laboratory (NPL), National Institute of Metrology (NIM), and National Institute of Standards and Technology (NIST). Most of the reported measurement results were generally consistent, while there was a small number of outlying values. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

Authors

Institutions

Publication Details

Journal
Metrologia
Published
2025-01-01
DOI
https://doi.org/10.1088/0026-1394/62/1a/01004
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CCEM key comparison CCEM.RF-K5c.CL

Alain Michaud, Karel Dražil, R. Judaschke, L. Oberto et al.
Metrologia
Particle accelerators and beam dynamics
article

CCEM key comparison CCEM.RF-K5c.CL

Alain Michaud, Karel Dražil, R. Judaschke, L. Oberto, Handan Sakarya, Ryoko Kishikawa, Faisal Mubarak, Erik Dressler, J. Stenarson, Jürg Rüfenacht, Masahiro Horibe, Djamel Allal, Daniel Stokes, Linoh A. Magagula, J.H. Howes, Alex Konyshev, Lukasz Usydus, Shan Yueyan, Meng Yusong
article en

Abstract

Main text An international measurement comparison, identified as CCEM.RF-K5c.CL, for scattering parameters and reflection coefficients by broad-band method was conducted between twenty national metrology institutes. The purpose of the comparison is to establish the calibration measurement capability of each participating laboratory. This report presents the key comparison reference values and degree of equivalence of each participant with respect to the key comparison reference values of the comparison. The participants measured seven travelling standards, an adapter, a 20 dB attenuator, a 40 dB attenuator, two matched terminations, and two flush short terminations with 3.5 mm coaxial connectors from 0.1 GHz to 33 GHz. The pilot laboratory is National Metrology Institute of Japan (NMIJ) and the supporting laboratories are Federal Institute of Metrology (METAS) and National Physical Laboratory (NPL), National Institute of Metrology (NIM), and National Institute of Standards and Technology (NIST). Most of the reported measurement results were generally consistent, while there was a small number of outlying values. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

MetrologiaVol. 62(1A)
Agency for Science, Technology and Research (SG), Physikalisch-Technische Bundesanstalt (DE), National Physical Laboratory (GB), Forskning.no (Norway) (NO), Swiss Federal Institute of Metrology (CH), Laboratoire National de Métrologie et d'Essais (FR), National Metrology Institute of South Africa (ZA), Tübitak National Metrology Institute (TR), Český metrologický institut (CZ), National Research Council (RO), Siberian State Order of the Red Banner of Labor Research Institute of Metrology (RU), Istituto Nazionale di Ricerca Metrologica (IT), Central Office of Measures (PL), VSL National Metrology Institute (NL)
Openalex Percentile: Top 76%
Particle accelerators and beam dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.