Comparison of the mass concentration of size-resolved particulate matter inside a selected fire station in Poland and in the atmospheric air in its immediate surroundings

The objective of this study was to evaluate the mass concentration of size-resolved (PM 1 , PM 2.5 , PM 4 , PM 10 , PM 100 ) particulate matter (PM) in the indoor air of a selected fire station in Poland and to compare them with the concentrations of the same PM fractions in the atmospheric air. Optical measurements of PM concentrations were conducted for 12 hours a day, simultaneously inside and outside of the fire station, for 14 days in heating and non-heating seasons. In both measurement seasons, the average PM concentrations were higher in the fire station (26–44 µg/m 3 ) than in the ambient air (9–32 µg/m 3 ). The proportion of fine particles in the total PM mass was found to be higher in the fire station (83–90%) than in the atmospheric air (40–78%). The findings of conducted analyses substantiate the notion that the concentrations and mass size distribution of PM in the fire station deviates from the concentrations and mass distribution for the urban background, a phenomenon that is attributable to the unique characteristics of the fire station and the prevalence of internal sources within it.

Authors

Publication Details

Journal
Environment Protection Engineering
Published
2025-01-01
DOI
https://doi.org/10.37190/epe250204
Citations
2
Primary Topic
Engine and Fuel Emissions
Type
article
Field-Weighted Citation Impact
1.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of the mass concentration of size-resolved particulate matter inside a selected fire station in Poland and in the atmospheric air in its immediate surroundings

Wioletta Rogula–Kozłowska, Karolina Bralewska, Jarosław Białas
2 citations
Environment Protection Engineering
Engine and Fuel Emissions
1.37
article

Comparison of the mass concentration of size-resolved particulate matter inside a selected fire station in Poland and in the atmospheric air in its immediate surroundings

Wioletta Rogula–Kozłowska, Karolina Bralewska, Jarosław Białas
article en
2 citations

Abstract

The objective of this study was to evaluate the mass concentration of size-resolved (PM 1 , PM 2.5 , PM 4 , PM 10 , PM 100 ) particulate matter (PM) in the indoor air of a selected fire station in Poland and to compare them with the concentrations of the same PM fractions in the atmospheric air. Optical measurements of PM concentrations were conducted for 12 hours a day, simultaneously inside and outside of the fire station, for 14 days in heating and non-heating seasons. In both measurement seasons, the average PM concentrations were higher in the fire station (26–44 µg/m 3 ) than in the ambient air (9–32 µg/m 3 ). The proportion of fine particles in the total PM mass was found to be higher in the fire station (83–90%) than in the atmospheric air (40–78%). The findings of conducted analyses substantiate the notion that the concentrations and mass size distribution of PM in the fire station deviates from the concentrations and mass distribution for the urban background, a phenomenon that is attributable to the unique characteristics of the fire station and the prevalence of internal sources within it.

Environment Protection EngineeringVol. 51(2)
Openalex Percentile: Top 18%
Engine and Fuel Emissions
1.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.