Tribotechnical Diagnostics – Analysis of Engine Oil Degradation Via Oil Properties of Sae 10w-30 in Tatra Phoenix During 9 Months of Use

This article discusses selected degradation elements in the context of tribodiagnostic measurement. Four engine oil (EO) measurements were made to monitor changes in selected properties during 4,546 km of operation. EO samples were taken from the Tatra 815 Phoenix at three-monthly intervals. All samples were measured in the tribodiagnostic laboratory of the Armed Forces Academy, Department of Mechanical Engineering, on SpectroVisc Q-3050, Spectro Q1000 Fluid Scan, SpectroCube, FeroCheck and an electron microscope to perform photo-documentation of the separation membrane and separation filter results. The paper presents the measurements on the SpectroCube, FeroCheck and the electron microscope in more detail.

Authors

Publication Details

Journal
Science & Military
Published
2025-01-01
DOI
https://doi.org/10.52651/sam.a.2025.1.16-29
Primary Topic
Technical Engine Diagnostics and Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tribotechnical Diagnostics – Analysis of Engine Oil Degradation Via Oil Properties of Sae 10w-30 in Tatra Phoenix During 9 Months of Use

Vladimír Kadlub, Miroslav Marko, Adam Fulek
Science & Military
Technical Engine Diagnostics and Monitoring
article

Tribotechnical Diagnostics – Analysis of Engine Oil Degradation Via Oil Properties of Sae 10w-30 in Tatra Phoenix During 9 Months of Use

Vladimír Kadlub, Miroslav Marko, Adam Fulek
article en

Abstract

This article discusses selected degradation elements in the context of tribodiagnostic measurement. Four engine oil (EO) measurements were made to monitor changes in selected properties during 4,546 km of operation. EO samples were taken from the Tatra 815 Phoenix at three-monthly intervals. All samples were measured in the tribodiagnostic laboratory of the Armed Forces Academy, Department of Mechanical Engineering, on SpectroVisc Q-3050, Spectro Q1000 Fluid Scan, SpectroCube, FeroCheck and an electron microscope to perform photo-documentation of the separation membrane and separation filter results. The paper presents the measurements on the SpectroCube, FeroCheck and the electron microscope in more detail.

Science & MilitaryVol. 20(1)
Openalex Percentile: Top 82%
Technical Engine Diagnostics and Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.