A Glycosyl-Imprinted Sensor Used for Accurate Classification and Quantification of Breast Cancer-Derived Exosomes by Electrochemiluminescence Detection of Two Glycoproteins at Dual Potentials

Early diagnosis of breast cancer remains a challenge. Tumor-derived exosomes are considered ideal biomarkers for liquid biopsies in early diagnosis because they carry genetic materials and proteins similar to those of tumor cells. In this paper, a glycosyl-imprinted electrochemiluminescence sensor was constructed as a specificity hunter to capture breast cancer exosomes by adsorbing the polysaccharides of exosomes PD-L1 on a glycosyl-imprinted polymer (GIP); then, PD-L1 and MUC1 were specifically labeled with the aptamer probes of Au@luminol-PD-L1 and Au@g-C<sub>3</sub>N<sub>4</sub>-MUC1, respectively. Breast cancer exosomes were identified by the GIP membrane, and then the potential-resolved ECL signals of the probes labeled on PD-L1 and MUC1 at cathodic (-1.4 V) and anodic (+0.7 V) potentials were recorded, respectively. The platform enables quantitative analysis of exosomes and the detection of exosome marker proteins PD-L1 and MUC1 in breast cancer. The determination ranges for PD-L1 and MUC1 were 2.10 × 10<sup>-4</sup> to 2.10 pg/mL and 1.88 × 10<sup>-3</sup> to 18.8 pg/mL, respectively, and the detection limits of PD-L1 and MUC1 were 0.105 fg/mL and 1.28 fg/mL, respectively. The determination range for exosomes was 2.36 × 10<sup>3</sup> to 2.36 × 10<sup>7</sup> exosomes/mL, and the detection limits of exosomes were 1.620 × 10<sup>3</sup> and 1.586 × 10<sup>3</sup> exosomes/mL via the signals of aptamer probes labeled on Au@luminol-PD-L1 and Au@g-C<sub>3</sub>N<sub>4</sub>-MUC1, respectively. Based on the simultaneous analysis of the coexistence-specific markers PD-L1 and MUC1 carried by breast cancer-derived exosomes by the GIP sensor, the selectivity for the identification of breast cancer-derived exosomes was improved, thereby greatly expanding the ability of glycosyl imprinting technology to identify breast cancer-derived exosomes and accurately distinguish breast cancer patients from healthy individuals, reducing the risk of false positives and providing a reliable tool for the clinical diagnosis of breast cancer.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-07-19
DOI
https://doi.org/10.1021/acssensors.4c03666
Citations
6
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
4.84

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Glycosyl-Imprinted Sensor Used for Accurate Classification and Quantification of Breast Cancer-Derived Exosomes by Electrochemiluminescence Detection of Two Glycoproteins at Dual Potentials

Lijuan Lin, Kui Luo, Tao Qin, Zejun Jiang et al.
6 citations
ACS Sensors
Advanced biosensing and bioanalysis techniques
4.84
article

A Glycosyl-Imprinted Sensor Used for Accurate Classification and Quantification of Breast Cancer-Derived Exosomes by Electrochemiluminescence Detection of Two Glycoproteins at Dual Potentials

Lijuan Lin, Kui Luo, Tao Qin, Zejun Jiang, Jianping Li, Ling Li
article en
6 citations

Abstract

Early diagnosis of breast cancer remains a challenge. Tumor-derived exosomes are considered ideal biomarkers for liquid biopsies in early diagnosis because they carry genetic materials and proteins similar to those of tumor cells. In this paper, a glycosyl-imprinted electrochemiluminescence sensor was constructed as a specificity hunter to capture breast cancer exosomes by adsorbing the polysaccharides of exosomes PD-L1 on a glycosyl-imprinted polymer (GIP); then, PD-L1 and MUC1 were specifically labeled with the aptamer probes of Au@luminol-PD-L1 and Au@g-C<sub>3</sub>N<sub>4</sub>-MUC1, respectively. Breast cancer exosomes were identified by the GIP membrane, and then the potential-resolved ECL signals of the probes labeled on PD-L1 and MUC1 at cathodic (-1.4 V) and anodic (+0.7 V) potentials were recorded, respectively. The platform enables quantitative analysis of exosomes and the detection of exosome marker proteins PD-L1 and MUC1 in breast cancer. The determination ranges for PD-L1 and MUC1 were 2.10 × 10<sup>-4</sup> to 2.10 pg/mL and 1.88 × 10<sup>-3</sup> to 18.8 pg/mL, respectively, and the detection limits of PD-L1 and MUC1 were 0.105 fg/mL and 1.28 fg/mL, respectively. The determination range for exosomes was 2.36 × 10<sup>3</sup> to 2.36 × 10<sup>7</sup> exosomes/mL, and the detection limits of exosomes were 1.620 × 10<sup>3</sup> and 1.586 × 10<sup>3</sup> exosomes/mL via the signals of aptamer probes labeled on Au@luminol-PD-L1 and Au@g-C<sub>3</sub>N<sub>4</sub>-MUC1, respectively. Based on the simultaneous analysis of the coexistence-specific markers PD-L1 and MUC1 carried by breast cancer-derived exosomes by the GIP sensor, the selectivity for the identification of breast cancer-derived exosomes was improved, thereby greatly expanding the ability of glycosyl imprinting technology to identify breast cancer-derived exosomes and accurately distinguish breast cancer patients from healthy individuals, reducing the risk of false positives and providing a reliable tool for the clinical diagnosis of breast cancer.

ACS SensorsVol. 10(8)
Guilin Medical University (CN), Guilin University of Technology (CN), Bioengineering Center (RU)
National Natural Science Foundation of China, Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials
Good health and well-being
Openalex Percentile: Top 5%
Advanced biosensing and bioanalysis techniques
4.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.