COMPARISON OF THE FUNCTIONAL OUTCOMES OF VOLAR PLATE VERSUS K – WIRES FIXATION FOR DISTAL RADIUS ARTICULAR FRACTURES

Background: Distal radius fractures (DRFs) are among the most common upper limb injuries, particularly affecting elderly osteoporotic individuals and young adults. Optimal surgical management for intra-articular DRFs remains debated, with volar locking plates and K-wire fixation being widely used techniques. Objective: To compare the short-term functional outcomes of volar locking plate versus K-wire fixation in adult patients with intra-articular distal radius fractures. Methods: This randomized controlled trial was conducted over six months at the Department of Orthopedics, Khyber Teaching Hospital, Peshawar. A total of 174 patients aged 30–65 years with distal radius fractures were enrolled and randomized into two equal groups. Group A (n=87) underwent volar locking plate fixation, and Group B (n=87) received percutaneous K-wire fixation. Patients were followed for six weeks, and functional outcomes were assessed using the Quick Disabilities of the Arm, Shoulder, and Hand (Quick DASH) score. Data were analyzed using SPSS version 26, with significance set at p≤0.05. Results: Group A showed significantly better functional outcomes, with 47.1% achieving excellent DASH scores compared to 31.0% in Group B. Poor outcomes were observed in 17.2% of patients in the K-wire group and none in the volar plate group. The mean DASH score was lower in the volar plate group (8.9 ± 4.7) versus the K-wire group (14.6 ± 6.2), indicating better function and recovery in the former. Conclusion: Volar locking plate fixation demonstrated superior early functional outcomes compared to K-wire fixation. It may be the preferred option in cases requiring faster rehabilitation and better early recovery, although both methods remain clinically viable.

Authors

Institutions

Publication Details

Journal
Insights-Journal of Health and Rehabilitation
Published
2025-07-19
DOI
https://doi.org/10.71000/z70ewg04
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

COMPARISON OF THE FUNCTIONAL OUTCOMES OF VOLAR PLATE VERSUS K – WIRES FIXATION FOR DISTAL RADIUS ARTICULAR FRACTURES

Mohd Shahid, Arif Gul, Mohammad Edrees Neckzad
1 links
Insights-Journal of Health and Rehabilitation
Orthopedic Surgery and Rehabilitation
article

COMPARISON OF THE FUNCTIONAL OUTCOMES OF VOLAR PLATE VERSUS K – WIRES FIXATION FOR DISTAL RADIUS ARTICULAR FRACTURES

Mohd Shahid, Arif Gul, Mohammad Edrees Neckzad
article en

Abstract

Background: Distal radius fractures (DRFs) are among the most common upper limb injuries, particularly affecting elderly osteoporotic individuals and young adults. Optimal surgical management for intra-articular DRFs remains debated, with volar locking plates and K-wire fixation being widely used techniques. Objective: To compare the short-term functional outcomes of volar locking plate versus K-wire fixation in adult patients with intra-articular distal radius fractures. Methods: This randomized controlled trial was conducted over six months at the Department of Orthopedics, Khyber Teaching Hospital, Peshawar. A total of 174 patients aged 30–65 years with distal radius fractures were enrolled and randomized into two equal groups. Group A (n=87) underwent volar locking plate fixation, and Group B (n=87) received percutaneous K-wire fixation. Patients were followed for six weeks, and functional outcomes were assessed using the Quick Disabilities of the Arm, Shoulder, and Hand (Quick DASH) score. Data were analyzed using SPSS version 26, with significance set at p≤0.05. Results: Group A showed significantly better functional outcomes, with 47.1% achieving excellent DASH scores compared to 31.0% in Group B. Poor outcomes were observed in 17.2% of patients in the K-wire group and none in the volar plate group. The mean DASH score was lower in the volar plate group (8.9 ± 4.7) versus the K-wire group (14.6 ± 6.2), indicating better function and recovery in the former. Conclusion: Volar locking plate fixation demonstrated superior early functional outcomes compared to K-wire fixation. It may be the preferred option in cases requiring faster rehabilitation and better early recovery, although both methods remain clinically viable.

Insights-Journal of Health and RehabilitationVol. 3(`4 (Health and Allied))
Khyber Teaching Hospital (PK), University of Peshawar (PK), Northwest General Hospital and Research Center (PK), Institute of Management Sciences Peshawar (PK), University of Engineering and Technology Peshawar (PK)
Openalex Percentile: Top 70%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies