Evaluation of Intracochlear Pressure and Fluid Distribution in 3D-Printed Artificial Cochlear Models and Human Petrous Bones

<b>Introduction:</b> The important factor in applying substances for inner ear therapy is the atraumatic execution, as well as effective concentration uniformly distributed in all regions of the cochlea within a reasonable time frame. This study investigates whether an additional cochlear opening ("second-hole technique") can improve fluid distribution and reduce intracochlear pressure during dye delivery into the cochlear models and human petrous bone. <b>Material and Methods:</b> Three experimental setups were used: an uncoiled scala tympani model, a full-scale 3D-printed cochlear model, and a human petrous bone. In all cases, 1% methylene blue-stained saline was infused using a cochlear catheter (MED-EL, Innsbruck, Austria) through the round window. Intracochlear pressure was measured via fiberoptic pressure sensors inserted through a burr hole (artificial cochlear models) or at the lateral semicircular canal (human petrous bone). A second hole was made on the helicotrema in the inner ear models or at the oval window of the human petrous bone to examine the effect of a second hole on intracochlear pressure and fluid distribution. Dye distribution and intracochlear pressure were measured in 3D artificial models at two flow rates (0.2 and 0.4 mL/h). The intracochlear pressure were measured in the human petrous bone at a fixed rate (0.4 mL/h). <b>Results:</b> The use of a second hole significantly improved dye distribution in 3D models at both flow rates (<i>p</i> < 0.05) and led to earlier saturation-level distribution. Intracochlear pressure remained significantly lower and more stable in models with a second hole (<i>p</i> < 0.05). In human petrous bones, pressure fluctuation was reduced by the second hole, though pressure still increased over time. <b>Conclusions:</b> Using a second-hole technique leads to a faster, uniform level of dye distribution throughout the cochlear models, as well as a lower intracochlear pressure, which can be assumed to be an essential factor for hearing preservation during dye application.

Authors

Institutions

Publication Details

Journal
Brain Sciences
Published
2025-07-20
DOI
https://doi.org/10.3390/brainsci15070771
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Intracochlear Pressure and Fluid Distribution in 3D-Printed Artificial Cochlear Models and Human Petrous Bones

Rayoung Kim, Ingo Todt, Matthias Schürmann, Lars‐Uwe Scholtz
Brain Sciences
Hearing Loss and Rehabilitation
article

Evaluation of Intracochlear Pressure and Fluid Distribution in 3D-Printed Artificial Cochlear Models and Human Petrous Bones

Rayoung Kim, Ingo Todt, Matthias Schürmann, Lars‐Uwe Scholtz
article en

Abstract

<b>Introduction:</b> The important factor in applying substances for inner ear therapy is the atraumatic execution, as well as effective concentration uniformly distributed in all regions of the cochlea within a reasonable time frame. This study investigates whether an additional cochlear opening ("second-hole technique") can improve fluid distribution and reduce intracochlear pressure during dye delivery into the cochlear models and human petrous bone. <b>Material and Methods:</b> Three experimental setups were used: an uncoiled scala tympani model, a full-scale 3D-printed cochlear model, and a human petrous bone. In all cases, 1% methylene blue-stained saline was infused using a cochlear catheter (MED-EL, Innsbruck, Austria) through the round window. Intracochlear pressure was measured via fiberoptic pressure sensors inserted through a burr hole (artificial cochlear models) or at the lateral semicircular canal (human petrous bone). A second hole was made on the helicotrema in the inner ear models or at the oval window of the human petrous bone to examine the effect of a second hole on intracochlear pressure and fluid distribution. Dye distribution and intracochlear pressure were measured in 3D artificial models at two flow rates (0.2 and 0.4 mL/h). The intracochlear pressure were measured in the human petrous bone at a fixed rate (0.4 mL/h). <b>Results:</b> The use of a second hole significantly improved dye distribution in 3D models at both flow rates (<i>p</i> < 0.05) and led to earlier saturation-level distribution. Intracochlear pressure remained significantly lower and more stable in models with a second hole (<i>p</i> < 0.05). In human petrous bones, pressure fluctuation was reduced by the second hole, though pressure still increased over time. <b>Conclusions:</b> Using a second-hole technique leads to a faster, uniform level of dye distribution throughout the cochlear models, as well as a lower intracochlear pressure, which can be assumed to be an essential factor for hearing preservation during dye application.

Brain SciencesVol. 15(7)
Bielefeld University (DE), Klinikum Bielefeld (DE)
Openalex Percentile: Top 83%
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.