Touch-Enabled Reversible Microfluidic Ultradense Chips for Convenient, High-Throughput Electrochemical Assays

Here, we present a new approach to reversibly bond microfluidic polydimethylsiloxane (PDMS) channels on low-cost, reproducible, scalable, compact, and ultradense multisensor SU-8-coated chips toward high-throughput electrochemical assays. Based on putting the outlets at the bottom of PDMS, the method only needs manually attaching this substrate on a flat surface, thus offering simplicity, throughput, and reversibility. While a plasma-mediated approach failed to provide leakage-free bonding, the reversibly bonded devices presented a high adhesion strength, withstanding a pressure of at least 5.1 MPa. Because the approach is high-pressure tolerant and reversible, it can deliver both long-term analyses and ease of sampling in-channel material for posterior manipulation/characterization and even sensor regeneration. Importantly, the bonding also delivers long-term shelf life and reusability. Three proof-of-concept applications are presented: (i) the electrodeposition of different nanostructured microelectrodes, followed by their downstream characterization and electrochemical tests, (ii) the long-term proliferation and monitoring of colorectal and breast cancer cells through electrochemical cell adhesion assays, along with the following regeneration of sensors and drug susceptibility testing, and (iii) the electrode fouling-amenable determination of phosphate in synthetic body fluids (urine and saliva) for health assessment purposes. High-throughput assays were provided by the chips from fast analyses in series utilizing a hand-held one-channel potentiostat. For instance, 45 analyses could be completed within ∼135 s. One should also note that the approach is compatible with different materials. Hence, future studies can explore this generalizable dry bonding to produce other microfluidic systems for diverse applications.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2025-07-21
DOI
https://doi.org/10.1021/acsami.5c08760
Citations
2
Primary Topic
Innovative Microfluidic and Catalytic Techniques Innovation
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Touch-Enabled Reversible Microfluidic Ultradense Chips for Convenient, High-Throughput Electrochemical Assays

Gabriel J. C. Pimentel, Flávio M. Shimizu, Iris Renata Sousa Ribeiro, C. Silva et al.
2 citations
ACS Applied Materials & Interfaces
Innovative Microfluidic and Catalytic Techniques Innovation
1.35
article

Touch-Enabled Reversible Microfluidic Ultradense Chips for Convenient, High-Throughput Electrochemical Assays

Gabriel J. C. Pimentel, Flávio M. Shimizu, Iris Renata Sousa Ribeiro, C. Silva, Rafael Everton Assunção Ribeiro da Costa, Renato S. Lima, Bruna M. Hryniewicz, Paula C. R. Corsato, Bruna Bragantin, Priscila da Silva
article en
2 citations

Abstract

Here, we present a new approach to reversibly bond microfluidic polydimethylsiloxane (PDMS) channels on low-cost, reproducible, scalable, compact, and ultradense multisensor SU-8-coated chips toward high-throughput electrochemical assays. Based on putting the outlets at the bottom of PDMS, the method only needs manually attaching this substrate on a flat surface, thus offering simplicity, throughput, and reversibility. While a plasma-mediated approach failed to provide leakage-free bonding, the reversibly bonded devices presented a high adhesion strength, withstanding a pressure of at least 5.1 MPa. Because the approach is high-pressure tolerant and reversible, it can deliver both long-term analyses and ease of sampling in-channel material for posterior manipulation/characterization and even sensor regeneration. Importantly, the bonding also delivers long-term shelf life and reusability. Three proof-of-concept applications are presented: (i) the electrodeposition of different nanostructured microelectrodes, followed by their downstream characterization and electrochemical tests, (ii) the long-term proliferation and monitoring of colorectal and breast cancer cells through electrochemical cell adhesion assays, along with the following regeneration of sensors and drug susceptibility testing, and (iii) the electrode fouling-amenable determination of phosphate in synthetic body fluids (urine and saliva) for health assessment purposes. High-throughput assays were provided by the chips from fast analyses in series utilizing a hand-held one-channel potentiostat. For instance, 45 analyses could be completed within ∼135 s. One should also note that the approach is compatible with different materials. Hence, future studies can explore this generalizable dry bonding to produce other microfluidic systems for diverse applications.

ACS Applied Materials & InterfacesVol. 17(32)
Universidade Federal da Paraíba (BR), Universidade Federal de São Carlos (BR), Universidade de São Paulo (BR), Universidade Estadual de Campinas (UNICAMP) (BR), Brazilian Center for Research in Energy and Materials (BR), Laboratório Nacional de Nanotecnologia, Universidade Federal do ABC (BR)
Fundação de Amparo à Pesquisa do Estado de São Paulo, Conselho Nacional de Desenvolvimento Científico e Tecnológico
Affordable and clean energy
Openalex Percentile: Top 19%
Innovative Microfluidic and Catalytic Techniques Innovation
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.