A Comparative Study of Indoor Accuracies Between SLAM and Static Scanners

This study presents a comprehensive comparison of static and SLAM (Simultaneous Localization and Mapping) laser scanners of both new and old generation in a controlled indoor environment of a standard commercial building with long, linear corridors and recesses. The aim was to assess both global and local accuracy, as well as noise characteristics, of each scanner. Methods: A highly accurate static scanner was used to generate a reference point cloud. Five devices were evaluated: two static scanners (Leica RTC 360 and Trimble X7) and three SLAM scanners (GeoSLAM ZEB Horizon RT, Emesent Hovermap ST-X, and FARO Orbis). Accuracy analysis included systematic and random error assessment, axis-specific displacement evaluation, and profile-based local accuracy measurements. Additionally, noise was quantified before and after data smoothing. Static scanners yielded superior accuracies, with the Leica RTC 360 achieving the best performance (absolute accuracy of 1.2 mm). Among SLAM systems, the Emesent Hovermap ST-X and FARO Orbis—both newer-generation devices—demonstrated significant improvements over the older-generation GeoSLAM ZEB Horizon RT. After smoothing, the noise levels of these new-generation SLAM scanners (approx. 2.1–2.2 mm) approached those of static systems. The findings underline the ongoing technological progress in SLAM systems, with the new-generation SLAM scanners becoming increasingly viable alternatives to static scanners, especially when speed, ease of use, and reduced occlusions are prioritized. This makes them well-suited for rapid indoor mapping applications, provided that the slightly lower accuracy is acceptable for the intended use.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-07-19
DOI
https://doi.org/10.3390/app15148053
Citations
3
Primary Topic
Robotics and Sensor-Based Localization
Type
article
Field-Weighted Citation Impact
14.98
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Comparative Study of Indoor Accuracies Between SLAM and Static Scanners

Jaroslav Braun, Ondřej Michal, R. Urban, Martin Štroner et al.
3 citations
Applied Sciences
Robotics and Sensor-Based Localization
14.98
article

A Comparative Study of Indoor Accuracies Between SLAM and Static Scanners

Jaroslav Braun, Ondřej Michal, R. Urban, Martin Štroner, Tomáš Křemen, Anna Chrbolková
article en
3 citations

Abstract

This study presents a comprehensive comparison of static and SLAM (Simultaneous Localization and Mapping) laser scanners of both new and old generation in a controlled indoor environment of a standard commercial building with long, linear corridors and recesses. The aim was to assess both global and local accuracy, as well as noise characteristics, of each scanner. Methods: A highly accurate static scanner was used to generate a reference point cloud. Five devices were evaluated: two static scanners (Leica RTC 360 and Trimble X7) and three SLAM scanners (GeoSLAM ZEB Horizon RT, Emesent Hovermap ST-X, and FARO Orbis). Accuracy analysis included systematic and random error assessment, axis-specific displacement evaluation, and profile-based local accuracy measurements. Additionally, noise was quantified before and after data smoothing. Static scanners yielded superior accuracies, with the Leica RTC 360 achieving the best performance (absolute accuracy of 1.2 mm). Among SLAM systems, the Emesent Hovermap ST-X and FARO Orbis—both newer-generation devices—demonstrated significant improvements over the older-generation GeoSLAM ZEB Horizon RT. After smoothing, the noise levels of these new-generation SLAM scanners (approx. 2.1–2.2 mm) approached those of static systems. The findings underline the ongoing technological progress in SLAM systems, with the new-generation SLAM scanners becoming increasingly viable alternatives to static scanners, especially when speed, ease of use, and reduced occlusions are prioritized. This makes them well-suited for rapid indoor mapping applications, provided that the slightly lower accuracy is acceptable for the intended use.

Applied SciencesVol. 15(14)
Czech Technical University in Prague (CZ)
Openalex Percentile: Top 2%
Robotics and Sensor-Based Localization
14.98
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.