GC-MS METHOD DEVELOPMENT AND VALIDATION FOR THE DETERMINATION OF GENOTOXIC TOSYLATES IN TENELIGLIPTIN

In this study, a specific and robust Gas Chromatography-Mass Spectrometry (GC-MS) method was meticulously developed, optimized, and validated for the precise determination of the genotoxic tosylate impurities in Teneligliptin. The method was optimized on an Agilent 5977B GC/MSD system equipped with a capillary column (HP-5MS, 30 m × 0.32 mm x 1.0 μm) using helium as the carrier gas. Detection of the impurities was achieved using selective ion monitoring mode at specific mass-to-charge ratios. The method excelled in validation for various parameters, including specificity, sensitivity, precision, linearity, accuracy, selectivity, and robustness. It demonstrated linear behavior in the concentration range of 0.54, 0.55, and 0.53 to 3.0 ppm with high correlation coefficients. The detection and quantitation limits of genotoxic tosylates for Teneligliptin were also determined.

Authors

Publication Details

Journal
RASAYAN Journal of Chemistry
Published
2025-01-01
DOI
https://doi.org/10.31788/rjc.2025.1839365
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

GC-MS METHOD DEVELOPMENT AND VALIDATION FOR THE DETERMINATION OF GENOTOXIC TOSYLATES IN TENELIGLIPTIN

P. Ilayaraja, P. Parthiban, M. Manivannan
RASAYAN Journal of Chemistry
Analytical Methods in Pharmaceuticals
article

GC-MS METHOD DEVELOPMENT AND VALIDATION FOR THE DETERMINATION OF GENOTOXIC TOSYLATES IN TENELIGLIPTIN

P. Ilayaraja, P. Parthiban, M. Manivannan
article en

Abstract

In this study, a specific and robust Gas Chromatography-Mass Spectrometry (GC-MS) method was meticulously developed, optimized, and validated for the precise determination of the genotoxic tosylate impurities in Teneligliptin. The method was optimized on an Agilent 5977B GC/MSD system equipped with a capillary column (HP-5MS, 30 m × 0.32 mm x 1.0 μm) using helium as the carrier gas. Detection of the impurities was achieved using selective ion monitoring mode at specific mass-to-charge ratios. The method excelled in validation for various parameters, including specificity, sensitivity, precision, linearity, accuracy, selectivity, and robustness. It demonstrated linear behavior in the concentration range of 0.54, 0.55, and 0.53 to 3.0 ppm with high correlation coefficients. The detection and quantitation limits of genotoxic tosylates for Teneligliptin were also determined.

RASAYAN Journal of ChemistryVol. 18(03)
Openalex Percentile: Top 80%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.