Performance evaluation of STATCOM placement in real-world power system through DOA-NVSP algorithm for congestion management and stability improvement

The study presents an assessment of STATCOM placement in 28-bus, 330kV Nigerian power network (NPN) using a DOA-NVSP approach. The NVSP was employed to define the security status and predict the suitable placement of the STATCOM. Thereafter, the DOA was employed to optimally site and size the STATCOM. However, the search agents of the DOA algorithm were restricted to select the best suitable placement from the NVSP suggested locations. The DOA produces two best search agents based on their fitness factor- Alpha and Beta. The results from these two were further evaluated for performance improvement in terms of the stability and congestion management. The response plot graph on voltage profile was achieved by determining the degree of deviation of each search agent to reference or ideal bus voltage. Thereafter, the nonlinear least square (NLS) was employed to fit and compare the ideal operating voltage from Alpha and Beta STACOM sizing corresponding voltages. The Levenberg-Marquardt (LM) and trust-region (TR) algorithm were considered for the training of the NLS. The results from the NLS analysis show 0.0266, 0.3171 and 0.0340 for SSE, R-square and Rmse, respectively, for LM algorithm and 0.0220, 0.3890 and 0.0309 for SSE, R-square and Rmse, respectively, for TR algorithm. Similarly, the decongestion of the transmission line after STATCOM placement at bus 16 was 11.3% and 9.3% for active and reactive power, respectively. The study concluded that the proposed model was able to improve the stability and congestion management of the NPN.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-07-21
DOI
https://doi.org/10.1038/s41598-025-11232-2
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance evaluation of STATCOM placement in real-world power system through DOA-NVSP algorithm for congestion management and stability improvement

Funso Kehinde Ariyo, Nnamdi Nwulu, Tayo Uthman Badrudeen
Scientific Reports
Power System Optimization and Stability
article

Performance evaluation of STATCOM placement in real-world power system through DOA-NVSP algorithm for congestion management and stability improvement

Funso Kehinde Ariyo, Nnamdi Nwulu, Tayo Uthman Badrudeen
article en

Abstract

The study presents an assessment of STATCOM placement in 28-bus, 330kV Nigerian power network (NPN) using a DOA-NVSP approach. The NVSP was employed to define the security status and predict the suitable placement of the STATCOM. Thereafter, the DOA was employed to optimally site and size the STATCOM. However, the search agents of the DOA algorithm were restricted to select the best suitable placement from the NVSP suggested locations. The DOA produces two best search agents based on their fitness factor- Alpha and Beta. The results from these two were further evaluated for performance improvement in terms of the stability and congestion management. The response plot graph on voltage profile was achieved by determining the degree of deviation of each search agent to reference or ideal bus voltage. Thereafter, the nonlinear least square (NLS) was employed to fit and compare the ideal operating voltage from Alpha and Beta STACOM sizing corresponding voltages. The Levenberg-Marquardt (LM) and trust-region (TR) algorithm were considered for the training of the NLS. The results from the NLS analysis show 0.0266, 0.3171 and 0.0340 for SSE, R-square and Rmse, respectively, for LM algorithm and 0.0220, 0.3890 and 0.0309 for SSE, R-square and Rmse, respectively, for TR algorithm. Similarly, the decongestion of the transmission line after STATCOM placement at bus 16 was 11.3% and 9.3% for active and reactive power, respectively. The study concluded that the proposed model was able to improve the stability and congestion management of the NPN.

Scientific ReportsVol. 15(1)
University of Johannesburg (ZA), Obafemi Awolowo University (NG)
Openalex Percentile: Top 84%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance evaluation of STATCOM placement in real-world power system through DOA-NVSP algorithm for congestion management and stability improvement — Funso Kehinde Ariyo, Nnamdi Nwulu, et al. · Scientific Reports (2025) | TGRS Research Map | TGRS