Advantages of carbon fibre-reinforced polyetheretherketone over titanium implants in spine SBRT: a phantom evaluation

This study evaluates the clinical feasibility of spine stereotactic body radiotherapy (SBRT) in the presence of titanium and carbon fibre-reinforced polyetheretherketone (CFR-PEEK) spinal implants using custom 3D-printed phantoms. The investigation focuses on the dosimetric accuracy, imaging challenges, and achievable localisation precision. Customised 3D-printed phantoms incorporating titanium and CFR-PEEK implants were computed tomography (CT) scanned, with and without metal artefact reduction (MAR) algorithms. Localisation accuracy was tested using Elekta XVI CBCT and Brainlab ExacTrac Dynamic. The dosimetric accuracy of the Monaco treatment planning system (TPS) was assessed under simple geometric conditions and for clinically realistic VMAT plans. Patient-specific quality assurance and phantom-based measurements using ionization chambers and radiochromic film were performed to evaluate delivered dose accuracy. Both Image Guided Radiotherapy (IGRT) systems achieved sub-millimetre localisation accuracy, with maximum deviations of 0.3 mm observed for titanium implants. The Monaco treatment planning system (TPS) demonstrated accurate dose modelling, with deviations < 1% for CFR-PEEK and < 2% for titanium implants in simple homogeneous arrangements. In complex VMAT plan deliveries, dosimetric measurements showed stronger agreement with TPS predictions for CFR-PEEK implants, with deviations < 3%. Titanium-based plans exhibited greater deviations, with localised dose discrepancies exceeding clinical tolerances of 5%. The application of MAR algorithms reduced these discrepancies to < 5%, ensuring clinically acceptable dosimetric accuracy. CFR-PEEK implants enhance clinical workflows due to reduced imaging artefacts and smoother dose distributions, making MAR corrections unnecessary. For titanium implants, MAR is essential to achieve clinically acceptable dosimetric accuracy, highlighting the robustness of CFR-PEEK for spine SBRT.

Authors

Institutions

Publication Details

Journal
Physical and Engineering Sciences in Medicine
Published
2025-07-21
DOI
https://doi.org/10.1007/s13246-025-01587-1
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advantages of carbon fibre-reinforced polyetheretherketone over titanium implants in spine SBRT: a phantom evaluation

Pejman Rowshanfarzad, Simon Goodall, Katherine Tonkin, Martin A. Ebert et al.
1 links
Physical and Engineering Sciences in Medicine
Advanced Radiotherapy Techniques
article

Advantages of carbon fibre-reinforced polyetheretherketone over titanium implants in spine SBRT: a phantom evaluation

Pejman Rowshanfarzad, Simon Goodall, Katherine Tonkin, Martin A. Ebert, Peter Rampant
article en

Abstract

This study evaluates the clinical feasibility of spine stereotactic body radiotherapy (SBRT) in the presence of titanium and carbon fibre-reinforced polyetheretherketone (CFR-PEEK) spinal implants using custom 3D-printed phantoms. The investigation focuses on the dosimetric accuracy, imaging challenges, and achievable localisation precision. Customised 3D-printed phantoms incorporating titanium and CFR-PEEK implants were computed tomography (CT) scanned, with and without metal artefact reduction (MAR) algorithms. Localisation accuracy was tested using Elekta XVI CBCT and Brainlab ExacTrac Dynamic. The dosimetric accuracy of the Monaco treatment planning system (TPS) was assessed under simple geometric conditions and for clinically realistic VMAT plans. Patient-specific quality assurance and phantom-based measurements using ionization chambers and radiochromic film were performed to evaluate delivered dose accuracy. Both Image Guided Radiotherapy (IGRT) systems achieved sub-millimetre localisation accuracy, with maximum deviations of 0.3 mm observed for titanium implants. The Monaco treatment planning system (TPS) demonstrated accurate dose modelling, with deviations < 1% for CFR-PEEK and < 2% for titanium implants in simple homogeneous arrangements. In complex VMAT plan deliveries, dosimetric measurements showed stronger agreement with TPS predictions for CFR-PEEK implants, with deviations < 3%. Titanium-based plans exhibited greater deviations, with localised dose discrepancies exceeding clinical tolerances of 5%. The application of MAR algorithms reduced these discrepancies to < 5%, ensuring clinically acceptable dosimetric accuracy. CFR-PEEK implants enhance clinical workflows due to reduced imaging artefacts and smoother dose distributions, making MAR corrections unnecessary. For titanium implants, MAR is essential to achieve clinically acceptable dosimetric accuracy, highlighting the robustness of CFR-PEEK for spine SBRT.

Physical and Engineering Sciences in MedicineVol. 48(3)
The University of Western Australia (AU), Genesis HealthCare (US), Sir Charles Gairdner Hospital (AU), Hollywood Orthopaedic Group (AU), Centre for Cancer Biology (AU)
University of Western Australia
Openalex Percentile: Top 76%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.