BCRT‐DETR: A Lightweight Blood Cell Detection Transformer Model for Enhanced Medical Diagnostics

In the biomedical field, the detection of microscopic images of blood cells is crucial for diagnosing of blood-related diseases. To enhance accuracy and real-time performance, we developed a blood cell real-time detection transformer (BCRT-DETR) to improve detection efficiency. A dynamic alignment integration backbone network (DAIBN) was introduced to address the spatial differences in features from diverse sources during multi-backbone information fusion. Additionally, a multi-scale parallel aggregation splicing (MPAS) module was integrated into the neck component to mitigate missed detections during cell feature extraction. The integration of high- and low-frequency (HiLo) attention with the attention-based intra-scale feature interaction (AIFI) module to form AIFI-HiLo effectively overcame the model's previous limitation of concentrating on regions with cellular density. The introduction of the retentive meet transformer block (RMT_Block) in the neck component further optimized the computational complexity, thereby increasing the detection speed. The experimental results indicated that, compared with the recent transformer-based real-time detection model, RT-DETR, BCRT-DETR achieved significant efficiency improvements with reductions of 33.8%, 51.1%, and 34.1% in parameters, giga floating-point operations per second (GFLOPs), and model size, respectively. Simultaneously, BCRT-DETR improved mAP50 and mAP50:95 by 0.8% and 1.6%, respectively, with mAP50 reaching 96.8%. Furthermore, BCRT-DETR demonstrated exceptional generalization capabilities across the blood cell detection, blood cell count and detection, and complete blood count datasets. Our model provides reliable technical support and offers innovative solutions for automated medical diagnosis.

Authors

Institutions

Publication Details

Journal
Biotechnology and Applied Biochemistry
Published
2025-07-21
DOI
https://doi.org/10.1002/bab.70030
Citations
1
Primary Topic
Digital Imaging for Blood Diseases
Type
article
Field-Weighted Citation Impact
1.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

BCRT‐DETR: A Lightweight Blood Cell Detection Transformer Model for Enhanced Medical Diagnostics

Xi Chen, Guohui Wang
1 citations
Biotechnology and Applied Biochemistry
Digital Imaging for Blood Diseases
1.28
article

BCRT‐DETR: A Lightweight Blood Cell Detection Transformer Model for Enhanced Medical Diagnostics

Xi Chen, Guohui Wang
article en
1 citations

Abstract

In the biomedical field, the detection of microscopic images of blood cells is crucial for diagnosing of blood-related diseases. To enhance accuracy and real-time performance, we developed a blood cell real-time detection transformer (BCRT-DETR) to improve detection efficiency. A dynamic alignment integration backbone network (DAIBN) was introduced to address the spatial differences in features from diverse sources during multi-backbone information fusion. Additionally, a multi-scale parallel aggregation splicing (MPAS) module was integrated into the neck component to mitigate missed detections during cell feature extraction. The integration of high- and low-frequency (HiLo) attention with the attention-based intra-scale feature interaction (AIFI) module to form AIFI-HiLo effectively overcame the model's previous limitation of concentrating on regions with cellular density. The introduction of the retentive meet transformer block (RMT_Block) in the neck component further optimized the computational complexity, thereby increasing the detection speed. The experimental results indicated that, compared with the recent transformer-based real-time detection model, RT-DETR, BCRT-DETR achieved significant efficiency improvements with reductions of 33.8%, 51.1%, and 34.1% in parameters, giga floating-point operations per second (GFLOPs), and model size, respectively. Simultaneously, BCRT-DETR improved mAP50 and mAP50:95 by 0.8% and 1.6%, respectively, with mAP50 reaching 96.8%. Furthermore, BCRT-DETR demonstrated exceptional generalization capabilities across the blood cell detection, blood cell count and detection, and complete blood count datasets. Our model provides reliable technical support and offers innovative solutions for automated medical diagnosis.

Biotechnology and Applied Biochemistry
Xi'an Technological University (CN)
Openalex Percentile: Top 18%
Digital Imaging for Blood Diseases
1.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

BCRT‐DETR: A Lightweight Blood Cell Detection Transformer Model for Enhanced Medical Diagnostics — Xi Chen, Guohui Wang · Biotechnology and Applied Biochemistry (2025) | TGRS Research Map | TGRS