Icing disasters can significantly reduce the reliability of overhead transmission lines, while limited budgets of power grid enterprises constrain the scale of investment. To improve investment efficiency, it is essential to balance the reliability and economic performance of anti-icing strategies. Most existing studies on the performance evaluation of anti-icing strategies for transmission lines focus primarily on reliability, neglecting their economic implications. To address this gap, this paper proposes a time-evolution-based performance evaluation model for overhead transmission line anti-icing strategies. First, a lifetime distribution function of transmission lines during the icing period is constructed based on the Nelson–Aalen method and metal deformation theory. Subsequently, a quantitative risk model for iced transmission lines is developed, incorporating the failure rate, value of lost load, and amount of lost load, providing a monetary-based indicator for icing risk. Finally, a performance evaluation method for anti-icing strategies is developed based on the risk quantification model. Implementation cost is treated as risk control expenditure, and strategy performance is assessed by integrating it with residual risk cost to identify the optimal strategy through composite cost analysis. The proposed model enables a comprehensive assessment of anti-icing strategy performance, improving the accuracy of strategy selection and achieving a dynamic balance between implementation cost and transmission line reliability. The case study results demonstrate that the proposed method effectively reduces the risk of failure in overhead transmission lines under ice disasters while lowering anti-icing costs. Compared with two existing strategy selection approaches, the strategy based on this method achieved 46.11% and 32.56% lower composite cost, and 60.26% and 48.41% lower residual risk cost, respectively.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-07-21
DOI
https://doi.org/10.3390/en18143870
Citations
1
Primary Topic
Icing and De-icing Technologies
Type
article
Field-Weighted Citation Impact
4.99
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Evaluation Model of Overhead Transmission Line Anti-Icing Strategies Considering Time Evolution

Xiaojuan Xi, Xuyang Li, Bing Fan, Yongjie Li et al.
1 citations
Energies
Icing and De-icing Technologies
4.99
article

Performance Evaluation Model of Overhead Transmission Line Anti-Icing Strategies Considering Time Evolution

Xiaojuan Xi, Xuyang Li, Bing Fan, Yongjie Li, Muzi Li, Zhengwei Guo
article en
1 citations

Abstract

Icing disasters can significantly reduce the reliability of overhead transmission lines, while limited budgets of power grid enterprises constrain the scale of investment. To improve investment efficiency, it is essential to balance the reliability and economic performance of anti-icing strategies. Most existing studies on the performance evaluation of anti-icing strategies for transmission lines focus primarily on reliability, neglecting their economic implications. To address this gap, this paper proposes a time-evolution-based performance evaluation model for overhead transmission line anti-icing strategies. First, a lifetime distribution function of transmission lines during the icing period is constructed based on the Nelson–Aalen method and metal deformation theory. Subsequently, a quantitative risk model for iced transmission lines is developed, incorporating the failure rate, value of lost load, and amount of lost load, providing a monetary-based indicator for icing risk. Finally, a performance evaluation method for anti-icing strategies is developed based on the risk quantification model. Implementation cost is treated as risk control expenditure, and strategy performance is assessed by integrating it with residual risk cost to identify the optimal strategy through composite cost analysis. The proposed model enables a comprehensive assessment of anti-icing strategy performance, improving the accuracy of strategy selection and achieving a dynamic balance between implementation cost and transmission line reliability. The case study results demonstrate that the proposed method effectively reduces the risk of failure in overhead transmission lines under ice disasters while lowering anti-icing costs. Compared with two existing strategy selection approaches, the strategy based on this method achieved 46.11% and 32.56% lower composite cost, and 60.26% and 48.41% lower residual risk cost, respectively.

EnergiesVol. 18(14)
North China Electric Power University (CN), Economic Research Institute (BG), Economic Research Institute (KZ)
Openalex Percentile: Top 5%
Icing and De-icing Technologies
4.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.