Performance Analysis and Cross-Calibration of PPC-40 and FC65-P Ionization Chambers in Low-Energy Electron Beams Absolute Dosimetry

Algorithm of electron beam dose delivery is dissimilar in comparison to X-ray radiation therapy. Therefore, absolute dosimetry of low energy like (≤9 MeV) is fundamentally effective in electron beam radiation therapy by a linear accelerator. This effectively needs evaluation of cross calibration by PPC-40 and FC65-P ionization chambers for accurate dosimetry to assure quality of treatment with clinical accuracy. Implications of results enunciated in this paper show that salient features are documented. The FC65-P chamber exhibited a deviation of up to 1.04% at shallow depths, indicating limitations for low-energy electron beams. In contrast, the PPC-40 demonstrated superior accuracy in surface dose and shallow-depth measurements due to its parallel-plate design and larger effective volume. The importance of cross-calibration yielded a new correction factor of 1.01, allowing conversion of FC65-P dose measurements to PPC-40 values. This relationship remained stable under controlled conditions. The clinical significance of the selection of ionization chamber for low energy electrons dosimetry is absolutely required for treatment precision and patient safety in electron beam radiation therapy (EBRT).

Authors

Institutions

Publication Details

Journal
International Journal of Medical Physics Clinical Engineering and Radiation Oncology
Published
2025-01-01
DOI
https://doi.org/10.4236/ijmpcero.2025.143008
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Analysis and Cross-Calibration of PPC-40 and FC65-P Ionization Chambers in Low-Energy Electron Beams Absolute Dosimetry

Abdul Momin, AKM Ahsan Habib, Motiur Rahman, Rubel Ahmed et al.
International Journal of Medical Physics Clinical Engineering and Radiation Oncology
Radiation Therapy and Dosimetry
article

Performance Analysis and Cross-Calibration of PPC-40 and FC65-P Ionization Chambers in Low-Energy Electron Beams Absolute Dosimetry

Abdul Momin, AKM Ahsan Habib, Motiur Rahman, Rubel Ahmed, Fajle Rabby, Ayesha Siddika Borna
article en

Abstract

Algorithm of electron beam dose delivery is dissimilar in comparison to X-ray radiation therapy. Therefore, absolute dosimetry of low energy like (≤9 MeV) is fundamentally effective in electron beam radiation therapy by a linear accelerator. This effectively needs evaluation of cross calibration by PPC-40 and FC65-P ionization chambers for accurate dosimetry to assure quality of treatment with clinical accuracy. Implications of results enunciated in this paper show that salient features are documented. The FC65-P chamber exhibited a deviation of up to 1.04% at shallow depths, indicating limitations for low-energy electron beams. In contrast, the PPC-40 demonstrated superior accuracy in surface dose and shallow-depth measurements due to its parallel-plate design and larger effective volume. The importance of cross-calibration yielded a new correction factor of 1.01, allowing conversion of FC65-P dose measurements to PPC-40 values. This relationship remained stable under controlled conditions. The clinical significance of the selection of ionization chamber for low energy electrons dosimetry is absolutely required for treatment precision and patient safety in electron beam radiation therapy (EBRT).

International Journal of Medical Physics Clinical Engineering and Radiation OncologyVol. 14(03)
IPB University (ID)
Affordable and clean energy
Openalex Percentile: Top 72%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance Analysis and Cross-Calibration of PPC-40 and FC65-P Ionization Chambers in Low-Energy Electron Beams Absolute Dosimetry — Abdul Momin, AKM Ahsan Habib, et al. · International Journal of Medical Physics Clinical Engineering and Radiation Oncology (2025) | TGRS Research Map | TGRS