Evaluation of Thermal Tissue Damage Using an Electrosurgical Instrument with Wear-Resistant Coatings

Cr-nanodiamond, WC, and Ni-P and Ni-W-P alloys were studied as functional coatings for electrosurgical instruments. Model experiments showed that the use of Ni-P (15.6 at.% P) and Ni-W-P (1.4 at.% W; 12.6 at.% P) coatings resulted in a decrease in the depth of thermal damage compared to an uncoated instrument. It was suggested that the functional properties of the coatings depend on a combination of many factors, including microhardness, roughness, and electrical conductivity; however, the contribution of any given factor requires more detailed study.

Authors

Institutions

Publication Details

Journal
Practice of Anticorrosive Protection
Published
2025-03-01
DOI
https://doi.org/10.31615/j.corros.prot.2025.115.1-2
Primary Topic
Thyroid and Parathyroid Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Thermal Tissue Damage Using an Electrosurgical Instrument with Wear-Resistant Coatings

Andrey B. Drovosekov, I. V. Goroncharovskaya, I. N. Myagkova, А. К. Евсеев et al.
4 links
Practice of Anticorrosive Protection
Thyroid and Parathyroid Surgery
article

Evaluation of Thermal Tissue Damage Using an Electrosurgical Instrument with Wear-Resistant Coatings

Andrey B. Drovosekov, I. V. Goroncharovskaya, I. N. Myagkova, А. К. Евсеев, A. А. Kanibolotskiy, N. A. Polyakov, I. I. Kirsanov, A. A. Saprin
article en

Abstract

Cr-nanodiamond, WC, and Ni-P and Ni-W-P alloys were studied as functional coatings for electrosurgical instruments. Model experiments showed that the use of Ni-P (15.6 at.% P) and Ni-W-P (1.4 at.% W; 12.6 at.% P) coatings resulted in a decrease in the depth of thermal damage compared to an uncoated instrument. It was suggested that the functional properties of the coatings depend on a combination of many factors, including microhardness, roughness, and electrical conductivity; however, the contribution of any given factor requires more detailed study.

Practice of Anticorrosive ProtectionVol. 30(1)
Bio-Medical Science (South Korea) (KR)
Openalex Percentile: Top 70%
Thyroid and Parathyroid Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.