A hierarchical fault location method for power lines based on instantaneous phase consistency

For power lines, fault analysis and fault point location methods face many challenges. To address this problem, a hierarchical fault point location method for power lines based on instantaneous phase consistency is proposed. According to the voltage instantaneous amplitude consistency constraint at the fault point, the fuzzy fault interval is determined using the dichotomy method; the fault judgment criterion is constructed based on the constraint that the instantaneous phase of the zero-sequence voltage and zero-sequence current on the transition resistor is consistent, and the golden section search algorithm is used to determine the precise location of the fault in the fault section. The positioning results of a large number of simulation cases and actual field cases show that the hierarchical fault point location method is accurate and effective, and the positioning method is not affected by factors such as fault type, line parameters, fault location, transition resistor value and time-varying characteristics. It is suitable for the analysis and fault point location of power line short-circuit faults, and can provide a reference for the handling of related problems.

Authors

Institutions

Publication Details

Published
2025-07-21
DOI
https://doi.org/10.1117/12.3075750
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A hierarchical fault location method for power lines based on instantaneous phase consistency

Liyuan He, Lanjiang Wu, Chuanwei Zhou
Power Systems Fault Detection
article

A hierarchical fault location method for power lines based on instantaneous phase consistency

Liyuan He, Lanjiang Wu, Chuanwei Zhou
article en

Abstract

For power lines, fault analysis and fault point location methods face many challenges. To address this problem, a hierarchical fault point location method for power lines based on instantaneous phase consistency is proposed. According to the voltage instantaneous amplitude consistency constraint at the fault point, the fuzzy fault interval is determined using the dichotomy method; the fault judgment criterion is constructed based on the constraint that the instantaneous phase of the zero-sequence voltage and zero-sequence current on the transition resistor is consistent, and the golden section search algorithm is used to determine the precise location of the fault in the fault section. The positioning results of a large number of simulation cases and actual field cases show that the hierarchical fault point location method is accurate and effective, and the positioning method is not affected by factors such as fault type, line parameters, fault location, transition resistor value and time-varying characteristics. It is suitable for the analysis and fault point location of power line short-circuit faults, and can provide a reference for the handling of related problems.

Dalian University of Technology (CN)
Climate action
Openalex Percentile: Top 80%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A hierarchical fault location method for power lines based on instantaneous phase consistency — Liyuan He, Lanjiang Wu, et al. · (2025) | TGRS Research Map | TGRS