Utilizing the adjustable Velcro system Compreflex® for patients with chronic venous leg ulcers: An observational multicenter clinical follow-up study

IntroductionVenous leg ulcers (VLUs) pose significant challenges that adversely affect patients' quality of life and result in considerable economic burdens. While existing compression therapies are effective, they are often hindered by complexity, discomfort, and environmental concerns.ObjectivesThis study aimed to evaluate the performance and safety of the adjustable Velcro system Compreflex®, an alternative to traditional four-layer bandaging, for patients with chronic venous leg ulcers. The evaluation was conducted through a clinical follow-up trial.MethodsThis prospective, non-randomized, multicenter, single-arm study included 98 patients with VLUs. The Compreflex® Standard Calf and Foot device was assessed based on wound closure rates, patient satisfaction, and edema reduction. Patients were followed up at specific intervals: after 1, 12, and 26 weeks. ResultsOf the 98 enrolled patients, 19 discontinued participation. The mean ulcer area decreased from 52.9 cm<sup>2</sup> (95% CI, 35.9-69.9 cm<sup>2</sup>) to 37.4 cm<sup>2</sup> (95% CI, 20.0-54.7 cm<sup>2</sup>) at 26 weeks (<i>p</i> < .001). The wound closure rate at 26 weeks was 24.3% (95% CI, 16.6-34.9%). Challenges related to self-application were minimal, highlighting the device's usability. A patient satisfaction rate of 76.8% was reported, based on a satisfaction score of six or higher.ConclusionThis study provides valuable real-world evidence supporting the effectiveness and usability of the Compreflex® device, as demonstrated by the high patient satisfaction rate, and highlights its potential as a promising alternative in compression therapy for venous leg ulcers.

Authors

Institutions

Publication Details

Journal
Phlebology The Journal of Venous Disease
Published
2025-07-20
DOI
https://doi.org/10.1177/02683555251357361
Citations
1
Primary Topic
Diagnosis and Treatment of Venous Diseases
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Utilizing the adjustable Velcro system Compreflex® for patients with chronic venous leg ulcers: An observational multicenter clinical follow-up study

Muhammad Idzdihar Idris, Harikrishna KR Nair, Ahmad Rafizi Hariz Ramli, A. Othman et al.
1 citations
Phlebology The Journal of Venous Disease
Diagnosis and Treatment of Venous Diseases
2.01
article

Utilizing the adjustable Velcro system Compreflex® for patients with chronic venous leg ulcers: An observational multicenter clinical follow-up study

Muhammad Idzdihar Idris, Harikrishna KR Nair, Ahmad Rafizi Hariz Ramli, A. Othman, Nabil Mohammad Azmi
article en
1 citations

Abstract

IntroductionVenous leg ulcers (VLUs) pose significant challenges that adversely affect patients' quality of life and result in considerable economic burdens. While existing compression therapies are effective, they are often hindered by complexity, discomfort, and environmental concerns.ObjectivesThis study aimed to evaluate the performance and safety of the adjustable Velcro system Compreflex®, an alternative to traditional four-layer bandaging, for patients with chronic venous leg ulcers. The evaluation was conducted through a clinical follow-up trial.MethodsThis prospective, non-randomized, multicenter, single-arm study included 98 patients with VLUs. The Compreflex® Standard Calf and Foot device was assessed based on wound closure rates, patient satisfaction, and edema reduction. Patients were followed up at specific intervals: after 1, 12, and 26 weeks. ResultsOf the 98 enrolled patients, 19 discontinued participation. The mean ulcer area decreased from 52.9 cm<sup>2</sup> (95% CI, 35.9-69.9 cm<sup>2</sup>) to 37.4 cm<sup>2</sup> (95% CI, 20.0-54.7 cm<sup>2</sup>) at 26 weeks (<i>p</i> < .001). The wound closure rate at 26 weeks was 24.3% (95% CI, 16.6-34.9%). Challenges related to self-application were minimal, highlighting the device's usability. A patient satisfaction rate of 76.8% was reported, based on a satisfaction score of six or higher.ConclusionThis study provides valuable real-world evidence supporting the effectiveness and usability of the Compreflex® device, as demonstrated by the high patient satisfaction rate, and highlights its potential as a promising alternative in compression therapy for venous leg ulcers.

Phlebology The Journal of Venous DiseaseVol. 41(3)
University Malaya Medical Centre (MY), Hospital Kuala Lumpur (MY), Sultan Haji Ahmad Shah Hospital (MY)
Openalex Percentile: Top 13%
Diagnosis and Treatment of Venous Diseases
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.