Sistem Kontrol dan Monitoring: Sterilisasi Micro-organism Pada Ruangan Pasien Rawat Inap Untuk Menurunkan Penyakit Menular

Sterilization rooms are a concern for patients in hospitals. Inpatients affected by infectious diseases require a special action room. Therefore, the application of the sterilization room control and monitoring system with IoT is proposed to overcome TB patients. The study technique covers the design and testing of the control system and IoT monitoring system with time variations of 60, 90, and 120 minutes. The results of the application of the control system application show that the time variation causes a decrease in current from 0.8A to 0.5A with a test time of 60 minutes, but inversely proportional to the voltage with a test time of 90 and 120 minutes, which increases by 3.2V-3.9V. While the results of monitoring data in the inpatient room have varying lag times ranging from 0.13 seconds, 0.8 seconds and 0.7 seconds. the average value of time variation and data transmission affects the decrease in the bacteria of the hospital room cleaning process. the longer the irradiation time, the number of bacteria will decrease. Sterilizer control and monitoring system is used as a recommendation for infectious diseases in the inpatient room in the hospital.

Authors

Institutions

Publication Details

Journal
Journal Electric Field
Published
2025-06-24
DOI
https://doi.org/10.63440/jef.v2i1.100
Primary Topic
Intravenous Infusion Technology and Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sistem Kontrol dan Monitoring: Sterilisasi Micro-organism Pada Ruangan Pasien Rawat Inap Untuk Menurunkan Penyakit Menular

M. Najib Fikri Fadillah, Adi Mulyadi
Journal Electric Field
Intravenous Infusion Technology and Safety
article

Sistem Kontrol dan Monitoring: Sterilisasi Micro-organism Pada Ruangan Pasien Rawat Inap Untuk Menurunkan Penyakit Menular

M. Najib Fikri Fadillah, Adi Mulyadi
article en

Abstract

Sterilization rooms are a concern for patients in hospitals. Inpatients affected by infectious diseases require a special action room. Therefore, the application of the sterilization room control and monitoring system with IoT is proposed to overcome TB patients. The study technique covers the design and testing of the control system and IoT monitoring system with time variations of 60, 90, and 120 minutes. The results of the application of the control system application show that the time variation causes a decrease in current from 0.8A to 0.5A with a test time of 60 minutes, but inversely proportional to the voltage with a test time of 90 and 120 minutes, which increases by 3.2V-3.9V. While the results of monitoring data in the inpatient room have varying lag times ranging from 0.13 seconds, 0.8 seconds and 0.7 seconds. the average value of time variation and data transmission affects the decrease in the bacteria of the hospital room cleaning process. the longer the irradiation time, the number of bacteria will decrease. Sterilizer control and monitoring system is used as a recommendation for infectious diseases in the inpatient room in the hospital.

Journal Electric FieldVol. 2(1)
Universitas Pgri Banyuwangi (ID), Rumah Sakit Umum Pusat Dr. Sardjito (ID)
Openalex Percentile: Top 84%
Intravenous Infusion Technology and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.