Determining the Optimal Length of Root Canal Obturations Using GuttaFlow®2 and Thermafill Systems.

Introduction: Successful endodontic therapy requires complete mechanical and chemical preparation of the root canal system, followed by three-dimensional obturation. Inadequate obturation, despite proper cleaning and shaping, may lead to treatment failure. This study aims to compare the obturation length achieved using the GuttaFlow®2 and Thermafill systems, evaluating their effectiveness through micro-computed tomography (micro-CT). Materials and Methods: Eighty extracted human anterior teeth were decoronated 1 mm below the cementoenamel junction and randomly assigned to two groups. Group 1 (n=40) was obturated with GuttaFlow®2 (Coltene/Whaledent, Germany), and Group 2 (n=40) with Thermafill (Dentsply DeTrey, Germany). All samples were scanned using a cone-beam micro-CT system (μCT 35, SCANCO Medical, Switzerland) to assess the length and quality of canal obturation. Results: Statistical analysis using the Kruskal-Wallis ANOVA test (H=4.0383, p=0.2574) showed no significant difference in obturation length between the two groups. Both cold (GuttaFlow®2) and warm (Thermafill) techniques achieved optimal filling lengths, indicating that obturation quality is not significantly influenced by the type of material or technique. Conclusion: Both GuttaFlow®2 and Thermafill systems are effective in achieving the desired obturation length. The choice between warm and cold obturation techniques may be based on clinician preference, as neither demonstrated superiority in this study.

Authors

Institutions

Publication Details

Journal
Albanian Journal of Trauma and Emergency Surgery
Published
2025-07-20
DOI
https://doi.org/10.32391/ajtes.v9i2.480
Primary Topic
Tribology and Lubrication Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determining the Optimal Length of Root Canal Obturations Using GuttaFlow®2 and Thermafill Systems.

Nexhmije Ajeti, Amela Cana, Lindihana Emini, Jetmire Alimani-Jakupi et al.
Albanian Journal of Trauma and Emergency Surgery
Tribology and Lubrication Engineering
article

Determining the Optimal Length of Root Canal Obturations Using GuttaFlow®2 and Thermafill Systems.

Nexhmije Ajeti, Amela Cana, Lindihana Emini, Jetmire Alimani-Jakupi, Zana Jusufi-Osmani, Sahmedin Saliu
article en

Abstract

Introduction: Successful endodontic therapy requires complete mechanical and chemical preparation of the root canal system, followed by three-dimensional obturation. Inadequate obturation, despite proper cleaning and shaping, may lead to treatment failure. This study aims to compare the obturation length achieved using the GuttaFlow®2 and Thermafill systems, evaluating their effectiveness through micro-computed tomography (micro-CT). Materials and Methods: Eighty extracted human anterior teeth were decoronated 1 mm below the cementoenamel junction and randomly assigned to two groups. Group 1 (n=40) was obturated with GuttaFlow®2 (Coltene/Whaledent, Germany), and Group 2 (n=40) with Thermafill (Dentsply DeTrey, Germany). All samples were scanned using a cone-beam micro-CT system (μCT 35, SCANCO Medical, Switzerland) to assess the length and quality of canal obturation. Results: Statistical analysis using the Kruskal-Wallis ANOVA test (H=4.0383, p=0.2574) showed no significant difference in obturation length between the two groups. Both cold (GuttaFlow®2) and warm (Thermafill) techniques achieved optimal filling lengths, indicating that obturation quality is not significantly influenced by the type of material or technique. Conclusion: Both GuttaFlow®2 and Thermafill systems are effective in achieving the desired obturation length. The choice between warm and cold obturation techniques may be based on clinician preference, as neither demonstrated superiority in this study.

Albanian Journal of Trauma and Emergency SurgeryVol. 9(2)
State University of Tetova (MK), American Association of Endodontists (US), International Balkan University (MK)
Openalex Percentile: Top 83%
Tribology and Lubrication Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.